1. TECHNICAL DATAS
Power:
2000 Watt
IPX5
Infrared Heater protected against rain
220-240V 50/60 Hz Class I
2. EQUIPMENT
Appliances WR65 IPX5 are supplied complete with:
➢ Steel body in aluminium alloy, kiln varnishing with epoxy powders.
➢ Reflecting parabola made of polished ultra pure aluminium, anodically oxidised.
➢ Thermo resistant safety ceramic front glass.
➢ Wall connection
➢ Silicone rubber seal gasket
➢ Electric cable mt 3 with shuko plug
3. INSTALLATION OF WR65 IPX5
FIXING TO WALL
To install the appliance please observe the following minimum distances:
-
cm 32 from the ceiling, cm 100 from the wall
-
fixing height cm 250/350
Do not place the heater immediately under a power socket.
To get the best heating performance, the ideal positioning of the appliance is 45° inclined downwards, and the appliance
to be fixed perfectly horizontal.
4. POSITIONING WR65 IPX5
 Adjust the WR65 IPX5 reflector in the direction of the required heating bundle, when installing on a wall. It is usually a
45° inclination related to the horizontal line.
 The appliance must never be installed on a flammable surface, WR65 IPX5 must be placed at a safe distance (clear
space) of minimum 2.0 m. from combustible materials such as: cartons, fabrics, curtains etc. as well as glass walls.
 If placed in workshops and garages where there are flammable paints and liquids, WR65 IPX5 must be placed at a
minimum distance of 4 m. from the source of danger.
 We suggest not to use WR65 IPX5 in particularly dusty and closed areas. This could damage the bulb.
 When mounting inside a bathroom, always respect the minimum distances from showers and baths, and ensure
compliance with CEE-CEI.
 Furthermore, the commands to adjust the appliance and turn it on and off must not be within reach of the shower or
bath.
5. CLEANING
The cover and bulb must be kept clean to maintain the heater's original heat efficiency. Use only denatured alcohol and a
clean cloth. Other products may damage the heater.
6. INSTRUCTIONS FOR REPLACING THE BULB
WARNING - The WR65 IPX5 guarantee does not cover replacement or repair of the bulb. To change the bulb contact a
professionally qualified electrician or assistance service.
30
If necessary, call our Technical Service. Technical Office tel. 02/90639261