3. FIL PILOTE (GREEN LED)
The FIL PILOTE is a special communication protocol that enables the radiator to be
controlled by a special control unit. The mode is managed by the control unit, while
temperature control is managed by the user on the chronothermostat.
To switch from the programming mode to FIL PILOTE mode, press the MODE key once.
The letters "FP" will briefly appear.
1)
Comfort : SET POINT = comfort mode temperature
2)
Night reduction: SET POINT = comfort - 3.5°C
3)
ECO1 : SET POINT = comfort -1°C
4)
ECO2 : SET POINT = comfort -2°C
5)
FROST PROTECTION: SET POINT = 7°C
6)
Stop: no temperature control, radiator off. STAND-BY mode.
The reference temperatures are those set in comfort mode.
To return to stand-by mode - and consequently not to heat up -
press the STAND-BY key for 2 seconds.
The screen displays the word "OFF" for an instant (red LED).
[Fig. 12]
4. COMFORT MODE (GREEN LED)
To switch from FIL PILOTE mode to COMFORT mode, press the MODE key once. "CON"
will briefly appear accompanied by a sound. In COMFORT mode, you can adjust the
temperature with the PLUS and MINUS keys. The radiator stays on until the temperature
selected is reached.
The COMFORT program is indicated by an arrow on the left on the sun symbol and the
comfort temperature is displayed on the screen. The temperature selected is used for
weekly programming (par. 8) as a comfort level and in FIL PILOTE mode (par. 3) as a
comfort temperature.
[Fig. 13]
5. NIGHT MODE (green LED)
To switch from COMFORT mode to NIGHT mode, press the MODE key once. The letters
"RID" (Reduction) will briefly appear accompanied by a sound.
In NIGHT mode, you can adjust the temperature with the PLUS and MINUS keys.
This temperature is independent of the comfort temperature.
The night reduction program is indicated by the arrow on the moon symbol, and when the
screen displays the night temperature. The temperature selected is used for weekly
programming (par. 8) and as a night temperature level.
[Fig. 14]