Electrical Connections
Risk of severe injury or death by electrical shock.
• Always disconnect the electrical power before touching the pump, discharge or electrical plug when water is
present in the area.
• Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if
required by code.
IMPORTANT: If the power cord is damaged, the whole unit must be replaced
1. Connect the power cord to a constant source of power matching the pump nameplate voltage.
• Connect the pump to its own circuit, with no other electric receptacles or equipment in the cir-
cuit.
• Do not connect to a voltage other than that shown.
• Ensure that the fuses or circuit breaker are of ample capacity in the electrical circuit.
NOTE: Do not connect to a fan or any device that runs intermittently.
2. Install a thermal or overload protection control.
Single-Phase
Blue
White
Motor
Black
Impeller Rotation
NOTE: These instructions apply to only 3-phase pumps.
1. Ensure the circuit breakers are in the "OFF" position.
2. Lay pump on the side to observe the direction of rotation through the intake.
3. Turn circuit breakers to the "ON" position.
4. Make sure the impeller is rotating counter-clockwise.
5. To change the rotation, interchange any two of the white, red, or black wires of the pump at the dis-
connect box.
Feed-Thru Terminals
Red
A
Capacitor
Black
Blue
B
Green
Brown
C
Black
Red
Motor
To Power
Yellow/White
INSTALLATION
Electrical Connections
3-Phase
Feed-Through Terminals
Black
A
Red
B
Green
To Power
White
C
5