Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or
accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is mounting at the screw-on base with four screws M6 (in delivery
scope). As option there are this mounting accessories:
Permanent Holding Magnet CENALED screw-on base
Table clamp CENALED screw-on base
Wall angle bracket CENALED screw-on base
5 | Connection
The 24V DC LED light comes with a pre-assembled 3 m sensor cable (PVC, oil resistant, 2 open ends) for direct connection
to e.g. a machine control unit.
cable strand, brown
cable strand, black
For further connection options, like cables, plugs or materials you can find in the accessories of LED2WORK.
6 | Maintenance and Care
The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information
contained in this manual).
The LED light sources mounted in the light are connected to the luminaire housing in a special way (thermal coupling)
and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other compo-
nents may impair the tightness of the light. That is the reason why repairs may only be carried out by the manufactu-
rer or by persons authorised and qualified by the manufacturer.
Turn off the light before cleaning and let it cool down completely. Clean the outside of the light with a soft, dry and clean
cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may cause
discolouration of the housing.
7 | Warranty
When mounting the light, make sure that the luminaire is fastened securely and stably. If
the light falls down, its weight poses a risk of injury!
+24V DC
GND
To turn on the light, activate the push button on top the head of the light. Hold on the push
button for setting of the light intensity. Another pushing of the button turns the light off.
Do not open the light!
No liability is assumed for damages resulting from the use of unsuitable cleaning agents.