Accuracy Check of the Distance Measurement
The accuracy of the distance measurement can be checked
as follows:
– Select a permanent measuring section with a length
of approx. 3 ft to 33 ft (1 m to 10 m); its length must
be precisely known (e.g. the width of a room or a door
opening). The measuring distance must be indoors; the
target surface for the measurement must be smooth and
reflect well.
– Measure the distance 10 times after another.
The deviation of the individual measurements from the
mean value must not exceed ±1/16" (±1.5mm). Log the
measurements, so that you can compare their accuracy at a
later point of time.
Temperature
measurement not possible
Measuring tool not within the
temperature range between
+14°F and 113°F ( –10°C
and +45°C)
Battery low indicator (b) appears
Battery voltage decreasing
(measurement still possible)
Battery low indicator (b) flashing; measurement not
possible
Battery voltage too low
All indicators on the display flashing
The
defective
2610047629.indd 19
Troubleshooting
Cause
warning
measuring
tool
Corrective Measure
indicator
Wait until the measuring tool
has reached the operating
temperature
Replace batteries
Replace batteries
is
Contact
the
Service
(a)
flashing;
Customer
19