Télécharger Imprimer la page

Kity PS 1200 Traduction Á Partir De La Notice Originale page 45

Publicité

Warning: In the interests of operational safety, always switch off the saw and remove the mains plug before carrying out maintenance
work.
Problem
Possible Cause
Fastening nut tightened insufficiently
Saw blade gets loose after
turning off the motor
Motor does not start
No motor output turns off
Overload by dull saw blade, thermoprotection is
automatically
triggered
surface
Troubleshooting table
Help
Tighten fastening nut, M20 left-handed thread
manual
Insert a sharpened saw blade; motor can be
turned on again after the cooling period
longitudinal cuts
Align the slide carriage with the saw blade
45

Publicité

loading

Ce manuel est également adapté pour:

301 1302 916