Installation Instructions
WATER DRAINAGE
Remove the
upper drain plug
Continuous
drain hose
• During dehumidifying modes, remove the upper drain plug from the back of
the unit, install the drain connector (5/8 in. universal female connecter) with
3/4 in. hose (not included). For the models without a drain connector, just
attach the drain hose to the hole. Place the open end of the hose directly over
the drain area in your basement fl oor. Please refer to Fig. 20.
NOTE: Make sure the hose is secure so there are no leaks. Direct the hose
toward the drain, making sure that there are no kinks that will stop the water
from fl owing. Place the end of the hose into the drain and make sure the end
of the hose is down to let the water fl ow smoothly, (see Fig. 20). Never raise
it.
• When the water level of the bottom tray reaches a predetermined level,
the unit beeps 8 times, the digital display area shows P1. At this time the air
Fig.20
conditioning/dehumidifi cation process will immediately stop. However, the
fan motor will continue to operate (this is normal). Carefully move the unit to
a drain location, remove the bottom drain plug and let the water drain away
(Fig. 21). Restart the machine until the P1 symbol disappears. If the error
repeats, call for service.
NOTE: When operating or draining water, always protect carpeting or fl oors
from possible water spillage.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Fig.21