Télécharger Imprimer la page

Kohler K-1110-AH Guide Du Propriétaire page 14

Baignoire à hydromassage

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting (cont.)
User Keypad and Pump
Symptoms
12. Noisy operation.
Effervescent Ports
Symptoms
1.
Effervescent ports do not
work.
2.
Effervescent ports do not
bubble.
Chromatherapy Lights
Symptoms
1.
Chromatherapy lights do
not work.
Remote Control
Symptoms
1.
Remote control does not
work.
1023263-5-C
Probable Causes
A. Pump banding straps have not
been cut.
B. Dry or dislodged jet O-ring
(squeal).
Probable Causes
A. Whirlpool pump is not
operating.
B. Butterfly valve does not work.
C. Pump does not work.
D. Control does not work.
A. Air intake on suction line is
blocked.
B. Water flow is too low.
Probable Causes
A. Loose, disconnected or damaged
wiring/connections.
B. Control does not work.
Probable Causes
A. Batteries improperly installed or
dead.
B. Antenna on wiring harness is
damaged.
C. Remote control not programmed
correctly.
D. Remote control does not work.
E. Control does not work.
Recommended Action
A. Cut pump banding straps with tin
snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
Recommended Action
A. Turn on pump.
B. Replace butterfly valve.
C. Refer to the service manual to
troubleshoot the system. Refer to
installer/dealer.
D. Replace control.
A. Remove blockage.
B. Increase water flow.
Recommended Action
A. Check wiring for proper
connections. Replace wiring if
necessary.
B. Replace control.
Recommended Action
A. Replace batteries.
B. Replace wiring harness.
C. See homeowners guide or service
manual.
D. Replace remote control.
E. Replace control.
14
Kohler Co.

Publicité

loading