9.3 DÉPANNAGE AVEC
ERREUR
WATER INLET ERROR
Is
displayed?
Yes
Is filter inlet valve clogged
with foreign material?
No
Is the connector connected
to inlet valve disconnected
or disassembled?
No
Is resistance between each
terminal of inlet valve 4.2-
4.8kΩ?(Refer to 10-5
inlet
No
Is the voltage of the inlet
valve connector 220-240
V?( while the power is on)
No
Clean or
Yes
replace the
filter.
Reconnect
Yes
or repair the
connector.
Replace the
Yes
inlet valve
Replace the
Yes
inlet valve
33
Is the connector connected
to PCB disconnected or dis-
assembled?
No
Is Electrical connection
correct? (Refer to 10-5)
Yes
Is the water level frequency
below 24.6kHz? (Refer
8- 2)
No
Replace the PCB
[Note] Environnemental sécurité vérifier liste
1) Non eau robinet fuite
2) Non eau robinet geler
3) Non enchevêtrement de eau fournir tuyau
4) Non eau pénurie
5) Non rétrécissement sur eau fournir tuyau
exigible à une éventuelle mauvaise utilisation
de l'eau chaude et froide
6) Non eau fournir tuyau fuite
Reconnect
Yes
or repair the
connector.
Replace the
No
main harness
Replace the
to Yes
FWL sensor