Télécharger Imprimer la page

Ariston VELIS Serie Instructions Pour L'installation, L'emploi, L'entretien page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries'
disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagna-
tion should be avoided; it means the water heater should be used or flushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the preven-
tion of Legionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default.
Every time the product is switched on and every 30 days, the thermal disinfection cycle run to heat the
water heater up to 60°C.
Warning: when this software has been carrying out the thermal disinfection treatment, water temperature
can cause burns. Feel water before bathing or showering.
TECHNICAL CHARACTERISTICS
For the technical specifications, refer to the nameplate (the nameplate is located next to the water in-
take/outlet pipes).
Product range
Weight
Installation
Model
SMART
Q
elec
Q
elec , week, smart
Q
elec , week,
Load profile
L
wa
η
wa
V40
Volume available
The radio frequency band equipment operates is 2.4 GHz, and the maximum power of the transmitted signal is < 20dBm
The power consumption data in the table and the other information given in the Product Fiche (Annex A to this
manual) are defined in relation to EU Directives 812/2013 and 814/2013.
Products which do not have the label and Product Fiche required for boiler/solar power configurations pursu-
ant to regulation 812/2013 may not be used in such installations.
The appliance has a smart function which adapts consumption to the user's use profile.
If used properly, the appliance has a daily consumption of "Qelec (Q
of an equivalent product without the smart function.
The data on the energy label apply to the product when installed vertically
The appliance is conforming with international electrical safety standard IEC 60335-1; IEC 60335-2-21.
The CE marking applied to the appliance certifies that it conforms with the essential requirements of the
following European Directives:
- Low voltage directive (LVD): EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- Electromagnetic compatibility (EMC): EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RED directive. ETSI 301489-1, ETSI 301489-17
- ROHS 2 directive: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.
16 / EN
TABLE 1 - PRODUCT INFORMATION
45
kg
23,5
Vertical
x
kWh
7,290
kWh
25,234
kWh
32,166
M
40,0%
l
77
l
45
65
31
Vertical
Refer to the nameplate
x
7,443
25,456
34,333
M
15 dB
40,0%
110
65
/Q
elec, week, smart
elec, week
80
35,5
Vertical
x
7,099
26,560
31,860
M
39,6%
115
80
) which is less than that

Publicité

loading

Ce manuel est également adapté pour:

Velis 45Velis 65Velis 80