Ash or soot out of the
stove.
ALARM SIGNAL ON CONTROL PANEL
Alarm
Explication
ALAr
Pellet tank
Hot
temperature
PEL
is too high
(over the
consent).
ALAr
The
no
combustible
Acc
doesn't
inflame
during the
ignition
phase – No
fire bearing.
ALAr
Chimney
no
exhaust
ASP
fumes
blocked.
ALAr
Temperature
Sic
pellets tank
FAiL
or tangential
fan too
higher.
ALAr
Chimney
deP
exhaust
FAiL
fumes
blocked
IT IT IT IT- - - - GB
− The fire door is open
during combustion.
− No seal between the
combustion fan and
exhaus gas.
Possible reason
− Obstruction of top and
frontal air intake.
− Temperature feeler breaking.
− Breaking convection motor.
− No Pellets feed.
− Glow plug breaking
− No fire bearing from fumes
feeler.
− Pellets with ignition difficult.
− Chimney blocked.
− Electrical connection break
off.
− Pressure switch breaking.
− Up and Front Air intake
obstruction.
− Temperature thermostat
breaking.
− Convection Motor breaking.
− Chimney blocked.
− Electrical connection break
off
− Pressure switch breaking .
50/128
GB- - - - FR
FR- - - - ES
ES- - - - DE
DE mod. 730-730 ECO-730N 15a
GB
GB
FR
FR
ES
ES
DE
DE
− Please to close the fire door when
the stove is lighting.
− To seal every parts of exhaus
system and call the assistance
centre.
− Ignition harness could ne checked
only with apparatus not electrical
connected.
− Reparation has to be done by a
qualify staff.
Remedy
− To check the air intake.
− To substitute the feeler.
− To check convection motor
functioning.
− To check Pellets tank level .
− To check the screw feeder
function.
− To check electrical connection.
− To substitute the glow plug.
− To check position, function and
electrical connection of
temperature fumes feeler.
− To employ combustible of
good quality.
− To check the chimney.
− To check electrical connection.
− To substitute switch breaking.
− To check air intake.
− To substitute thermostat.
− To check convection motor
− Check the chimney.
− Check electrical connection.
− Substitute switch breaking.