Contact magnétique

Publicité

Description
The magnetic contact and the magnet must be mounted facing
each other in a window frame/door leaf and window
surround/door surround.
Caution:
Neither the contact nor the magnet can be installed
in ferromagnetic materials.
Special grade 3 magnetic contacts developed for installation in
ferromagnetic materials are available for this case.
The installation flange must only be mounted using screws
made of non-magnetic material.
When mounting is complete, the magnetic contact's electrical
switching function must be checked (for example, using a
continuity tester or multimeter).
The application of mechanical force, e.g., when mounting the
device on the casing may damage the glass body of the reed
switch.
Only cyanoacrylate adhesives (superglue) may be used to fix
the assembly parts. The processing instructions from the
respective manufacturer must be observed.
Distance Diagram
See Figure 3.
Minimum switch-on distance: 13 mm,
tolerance in x: max. ±3 mm
Proximity/switch-on distance
Distance/switch-off clearance
Technical Data
Flush-mounted magnetic contact DC128R4.7 for EOL zone
types, tamper protected, with 2 integrated 4k7 resistors
Note:
Only front flush and surface-mounting possible.
Contact type
Switching distance
Switching voltage
Switching current
Contact rating
Contact resistance
Breakdown voltage
Permissible operating voltage
Connection cable
External cable color
Internal conductor
Contact dimensions
Cable dimensions
Magnet
Housing material
2 / 10
Switch-on
Tolerance
distance [mm]
[mm]
±4
17
±4
22
1 - pin NC contact
17 mm, ±4 mm
max. 100 V DC
max. 500 mA
max. 6 W or 6 VA
max. 0.15 Ω
>250 V
max. 40 V
LIYY 2 x 0.14 mm Cu tin-plated;
Suitable for LSA IDC method of
termination
White
Blue
Ø 8 x 32 mm
Ø 3.2 mm x 2 m
Ø 6 x 30 mm AlNiCo 5, axially
polarized, in Ø 8 x 35 mm plastic
sleeve
S-B or A-B-S
Color
Temperature range
Protection category
Scope of Delivery
Ø
1 magnetic contact
1 magnet Ø 6 x 30 mm AlNiCo 5 in plastic sleeve
Ø
8 x 35 mm
2 installation flange EF 8/10 for wood, plastic and non-
magnetic metals
4 fastening screws DIN 7982 - 2.9 x 13 - V 2 A
Regulatory information
Manufacturer
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
EN
EN 50131-2-6 Grade 3 by VdS
VdS no.
G110012 (Cl. C)
Certification
European Union
Carrier Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see firesecurityproducts.com or
www.aritech.com.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
firesecurityproducts.com or www.aritech.com
P/N 31494400.Y71-ML • REV E • ISS 28NOV22
White
−25 to +70°C
VdS - environmental class III, IP 67
8 x 32 mm