Model GF4400A
Installation Manual
Please Read And Save These Instructions
USA Model
4400A (GFI #5961)
CAUTION!
!
This symbol and the word "CAUTION" indicates:
IMPORTANT INSTRUCTIONS!
Failure to heed
Inside The Box
• GA35 Vapor Pad
®
• Solenoid Valve Assembly
• GFX4 Digital Automatic Humidistat
Installation Hardware: 4400 is equipped with a 6' length plug-in receptacle cor
Tee Valve Quick Connect w/ Shut Off
CAUTION!
!
24V Transformer is Factory Installed. Do NOT Install a Separate 24Vac
Supply Source to the External Yellow & Red Wires.
Not Included (Contractor Supplied):
• 1/4" Diameter plastic supply tubing for cold water applications, or 1/4" copper
supply tubing for hot water applications
• Electrical wire and (2) wire nuts
• #8 x 1/2" Long self-piercing sheet metal screws or aluminum duct tape
• 24V Current sensing relay (GFGA50) or Air Pressure Proving Switch (GF12500)
WARNING:
Do not install where ambient temperatures fall below 32°F / 0° C or where plenum temperatures exceed 200° F / 93° C.
!
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
Form No. 4400-18 REV A
Canadian Model
GF4400A
!
!
CAUTION! or
WARNING! can result in serious injury or death.
Fan-Assist Evaporative Humidifiers
Supply Plenum Installation Location:
4400A fan-assist evaporative humidifier may be installed on
the supply plenum (ONLY) of a forced air handling system.
Select a location for the humidifier that allows for service and
maintenance.
Return
Vertical
Installation
Drain Line
WARNING!
!
This symbol and the word "WARNING" indicates:
IMPORTANT INSTRUCTIONS!
• WARNING:
DISCONNECT ELECTRICAL POWER
!
BEFORE BEGINNING INSTALLATION.
!
IMPORTANT:
To ensure your safety and the
longevity of your unit, we recommend:
• Contacting a licensed contractor to perform
maintenance or repairs.
• Changing your Vapor Pad
heating season.
Automatic
The model
Supply
6' Length
Plug-in
Receptacle
Cord
at the start of each
®
®
®

Publicité

loading

Sommaire des Matières pour GeneralAire GF4400A

  • Page 1 Model GF4400A Fan-Assist Evaporative Humidifiers Automatic Installation Manual Please Read And Save These Instructions Supply Plenum Installation Location: The model 4400A fan-assist evaporative humidifier may be installed on the supply plenum (ONLY) of a forced air handling system. Select a location for the humidifier that allows for service and maintenance.
  • Page 2 Model 4400A Humidifier Installation Manual INSTALLATION - SUPPLY (ONLY)  WARNING: For serviceability, please allow an obstruction-free zone of 4" on the right side and bottom of 12.13 High the humidifier. Cut a rectangular hole using the manufacturer-supplied Install the humidifier chassis, making sure the drain spout is template.
  • Page 3 Check flow of water through distributor trough and evaporator pad. Check fan operation (ON). Reduce RH% to desired setting after test completion. Connect the Humidistat (Typical Humidistat & Humidifier Installation Wiring Diagram) GFX4 Digital GENERALAIRE ® Automatic Control GFX4 HUMIDISTAT AIR PROVING SWITCH (FIELD...
  • Page 4 Your new humidifier carries a 5-year limited warranty. For our complete warranty policy visit www.GeneralAireIAQ.ca CONTACT General Filters, Inc. 43800 Grand River Avenue Novi, Michigan 48375 Toll Free: (866) 476-5101 www.generalaire.com Canadian General Filters, Ltd. 400 Midwest Rd Toronto, ON M1P3A9 Canadian General Filters Toll Free: (888) 216-9184 www.generalaireiaq.ca...
  • Page 5 Modèle 4400A Humidificateurs à Évaporation Assistés Par Ventilateur Guide d'installation Automatique Veuillez Lire Et Conserver Ces Instructions Emplacement d’installation du plénum: L’humidificateur à évaporation avec ventilateur 4400A peut (UNIQUEMENT) être installé sur le plénum d’un système de traitement à air pulsé. Installez l’humidificateur à...
  • Page 6 Manuel d'installation de l'humidificateur modèle 4400A INSTALLATION - ALIMENTATION (UNIQUEMENT)  AVERTISSEMENT: Pour faciliter l’entretien, veuillez laisser une zone sans obstruction de 4 po 12,13 po de du côté inférieur droit de hauteur l’humidificateur. Découpez un trou rectangulaire à l’aide du gabarit Installez le châssis de l’humidificateur en vous assurant que fourni par le fabricant.
  • Page 7 Connectez l'humidistat (schéma de câblage d'installation typique de l'humidistat et de l'humidificateur) GENERALAIRE Commande automatique HUMIDISTAT GFX4 numérique GFX4 PRESSOSTAT D’AIR (FOURNI SUR PLACE) HUMIDIFICATEUR À ÉVAPORATION AVEC VENTILATEUR 4400A GENERALAIRE FILS JAUNES ® ® FILS ROUGES ALIMENTATION DE 24 V CORDON D’ALIMENTATION...
  • Page 8 Votre nouvel humidificateur bénéficie d'une garantie limitée de 5 ans. Pour notre politique de garantie complète, visitez www.generalaireiaq.ca. COORDONNÉES Canadian General Filters, Ltd. 400 Midwest Rd Toronto, ON M1P3A9 Canadian General Filters (888) 216-9184 Numéro sans frais: www.generalaireiaq.ca Limited General Filters, Inc. 43800 Grand River Avenue Novi, Michigan 48375 (866) 476-5101 Numéro sans frais: www.generalaire.com...