Fresh Indoor Air Quality
INSTALLER: PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION IS
COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 150 degrees F. When wiring into a multi-speed blower circuit see Step 6.
INSTALLATION: The humidifier may be mounted with the 6" outlet to
the right or left by inverting the cabinet and reversing the positions of
the distributor trough and drain pan. The humidifier may be mounted
on the warm or return air plenum with equal efficiency.
See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper
supply tubing for hot water applications
2. 6" diameter galvanized by-pass pipe
3. electrical wire and wire nuts
4. current sensing relay (G.F. Model #GA50 suggested)
5. #8 self piercing sheet metal screws
1
8-7/8"
The GeneralAire model 570 may be installed on either the
supply or return plenum of a forced air handling system. Select
a location for the humidifier that allows for service and
maintenance. Cut out a rectangle 8-7/8" wide by 9-1/2" tall.
Extend horizontal centerline of cut out to the adjacent plenum.
Cut a 6" hole 10" to 15" from side of humidifier, on cabinet
centerline, using connecting collar as guide. The bypass is
reversible and can be mounted on the right or left side of the
humidifier.
2
Humidifier is self retaining. Slide top side in first, then slide
chassis down.
Level chassis and install center screws. If
by-pass pipe installs to opposite side of chassis, bend clip on
chassis, remove side discharge, and reinstall discharge to
opposite side of chassis. Install remaining four corner screws.
FORM NO. 570-18 REV. F
READ AND SAVE THESE INSTRUCTIONS
R
9-1/2"
1
2
RETURN AIR
WARM AIR
DRAIN
UP FLOW
GENERALAire
R
AC SERIES
HIGH EFFICIENCY AIR CLEANER
3 3
6"
Connect by-pass pipe to collar and humidifier cabinet. Using
holes at top and bottom of side panel discharge, pierce 2
self tapping screws through by-pass pipe.
4
COPPER
TUBING
PLASTIC
TUBING
Mount the self tapping saddle valve or code valve on either a cold
or a hot water pipe. A side or top mount is best to avoid clogging
from pipe sediment. Connect 1/4" O.D. tubing to the saddle valve.
Copper tubing requires a brass compression nut and brass sleeve.
Plastic tubing requires a brass insert inside the tubing, a plastic
sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.
570 SERIES
FLOW-THROUGH
BYPASS HUMIDIFIER
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
RETURN AIR
DRAIN
WARM AIR
WARM AIR
DOWN FLOW

Publicité

Table des Matières
loading

Sommaire des Matières pour GeneralAire 570 Serie

  • Page 1 9-1/2” 6” 8-7/8” The GeneralAire model 570 may be installed on either the Connect by-pass pipe to collar and humidifier cabinet. Using supply or return plenum of a forced air handling system. Select holes at top and bottom of side panel discharge, pierce 2 a location for the humidifier that allows for service and self tapping screws through by-pass pipe.
  • Page 2 GCV3412 CODE VALVE INSTALLATION INSTRUCTIONS Copper Pipe 1. Turn off water supply. 2. Clean pipe, fittings and valve with sandpaper or wire brush. 3. Apply a thin layer of flux to all surfaces to be soldered. 4. Assemble valve to pipe and/or fittings. 5.
  • Page 3: Care And Maintenance

    PARTS LIST FOR HUMIDIFIER 570-40 PAD RAIL 570-1 CHASSIS 900-9 NOZZLE GA-10 EVAPORATOR PAD 900-10 SPOUT GA4226 DISTRIBUTOR TUBE 900-15 DISTRIBUTOR TROUGH 900-11 DAMPER KNOB 900-28 DAMPER DISK 570-2 SIDE PANEL DISCHARGE 900-71 BADGE 570-13 COVER 900-14 DRAIN PAN GA4231 YELLOW ORIFICE GA4040 SOLENOID VALVE ASM P190 COMP.
  • Page 4: How The Humidifier Works

    1. Reduce the setting on the humidistat. Refer to CARE AND MAINTENANCE section of this manual to estimate a condensation on windows humidity setting for the home based on outside temperature. * 1. Replacement parts can purchased through your authorized General Aire contractor or visit www.GeneralAire.com Where can I purchase for more information.
  • Page 5 ELITE 570 HUMIDIFIER SPECIFICATIONS Expected Humidity Performance Coverage in Square Feet Based on Construction Type Average (0.50 AC/H) Tight (0.30 AC/H) Model No. Loose (0.75 AC/H) 2000 sq. ft. Elite 570 800 sq. ft. 1200 sq. ft. 1650 sq. ft. 2800 sq.
  • Page 6 WARRANTY REGISTRATION You may register online at www.GeneralAire.com or mail form below Product Information: Serial Number: _____________________________________________________________ Model: ____________________________________________________________________ Install Date: Month _______________ Day ______________ Year _____________ Fresh Indoor Air Quality Owner Information: Name: _____________________________________________________________________ Address: ___________________________________________________________________ Mail Form To:...
  • Page 7 (9-1/2 po) 22,5 cm (8-7/8 po) Le modèle 570 de GeneralAire peut être installé sur le plénum Raccorder le tuyau de dérivation au collier et au boîtier de d’alimentation ou de retour d’un système à air propulsé. Choisir l’humidificateur. Visser deux (2) vis autotaraudeuses dans les un emplacement pour l’humidificateur qui permette un accès...
  • Page 8 INSTRUCTIONS D’INSTALLATION DE LA VANNE-CODE GCV3412 Tuyau en cuivre 1. Couper l’alimentation en eau. 2. Nettoyer le tuyau, les raccords et la vanne avec du papier abrasif ou une brosse métallique. 3. Appliquer une fine couche de flux sur toutes les surfaces devant être soudées.
  • Page 9: Liste Des Pièces Pour L'humidificateur

    LISTE DES PIÈCES POUR L’HUMIDIFICATEUR 570-40 RAIL DU TAMPON 570-1 CADRE 900-9 GICLEUR GA-10 TAMPON D’ÉVAPORATION 900-10 BUSE GA4226 TUBE DE COMPRESSION 900-15 GOULOTTE DU DISTRIBUTEUR 900-11 BOUTON DU REGISTRE 900-28 DISQUE DU REGISTRE 570-2 ÉVACUATION PANNEAU LATÉRAL 900-71 INSIGNE 570-13 COUVERCLE 900-14 BAC DE RÉCUPÉRATION GA4231 ORIFICE JAUNE...
  • Page 10: Dépannage

    1. Des pièces de rechange peuvent être achetées auprès de votre installateur GeneralAire autorisé ou visiter le Où peut-on acheter des pièces de rechange? www.GeneralAire.com pour obtenir de plus amples informations.
  • Page 11: Caractéristiques De L'humidificateur Elite 570

    CARACTÉRISTIQUES DE L’HUMIDIFICATEUR ELITE 570 Performance d’humidité prévue selon la superficie en mètres carrés/pieds carrés et le type de construction Nº de modèle Moyen (0,50 CAH) Élevé (0,30 CAH) Faible (0,75 CAH) 111 m /1200 pi 186 m /2000 pi Elite 570 74 m /800 pi...
  • Page 12 ENREGISTREMENT DE LA GARANTIE Le produit peut être enregistré en ligne au www.GeneralAire.com ou par la poste en envoyant le formulaire ci-dessous Renseignements sur le produit : Numéro de série : ____________________________________________________________ Modèle : ___________________________________________________________________ Date d’installation : Mois _______________ Jour ______________ Année ____________ Qualité...

Ce manuel est également adapté pour:

Elite 570900 serieElite 900Elite 1000

Table des Matières