Publicité

Liens rapides

Model 1000 (A & M)
Installation & Owners Manual
Please Read And Save These Instructions
• Installation by anyone other than a qualified contractor voids the warranty.
• Product designed for residential installation only. Commercial installation voids warranty.
• Modification or alteration of product, parts, installation instructions or local safety codes voids warranty.
General Filters, Inc.
43800 Grand River Avenue
Novi, Michigan 48375
Toll Free: (866) 476-5101
www.generalaire.com
• Read our full warranty policy at the end of this document.
Canadian General Filters, Ltd.
400 Midwest Rd.
Toronto, ON M1P3A9 Canada
Toll Free: (888) 216-9184
www.cgfproducts.com
Breathe Healthier
Humidifier
GFI #5730 & 5735

Publicité

Table des Matières
loading

Sommaire des Matières pour GeneralAire 1000A

  • Page 1 • Installation by anyone other than a qualified contractor voids the warranty. • Product designed for residential installation only. Commercial installation voids warranty. • Modification or alteration of product, parts, installation instructions or local safety codes voids warranty. • Read our full warranty policy at the end of this document. Breathe Healthier General Filters, Inc. Canadian General Filters, Ltd. 43800 Grand River Avenue 400 Midwest Rd. Novi, Michigan 48375 Toronto, ON M1P3A9 Canada Toll Free: (866) 476-5101 Toll Free: (888) 216-9184 www.generalaire.com www.cgfproducts.com...
  • Page 2: Table Des Matières

    Model 1000 Humidifier Installation Manual Model 1000 Table of Contents Table of Contents Specifications Unit Location Additional Materials That May Be Necessary: Installation Installing The Control Final Steps Of Installation How The Humidifier Works Maintenance Parts Drawing Humidifier Chassis Cut Out Inside Your Box Trouble Shooting FAQ’s...
  • Page 3: Specifications

    Model 1000 Humidifier Installation Manual Specifications • Model: 1000 (A & M) Elite Flow Through Humidifiers (GFI #5730 & #5735) • Type: Fan Powered Flow Through • GPD: 18 Based on 120° F / 49° C Plenum Temperature • Warranty (Years): 10 • Replacement Vapor Pad : GA19 (GFI#7919) (Replace 1-2 times per season) ®...
  • Page 4: Installation

    Model 1000 Humidifier Installation Manual Installation 1. Select a location on the vertical surface of warm air plenum of a forced air handling system for mounting humidifier that allows for service and maintenance. Do not install humidifier where the blanked off ends of a cooling coil will restrict air flow to the humidifier.
  • Page 5: Installing The Control

    Model 1000 Humidifier Installation Manual Installation Cont. 5. GCV3412 Code Valve Installation Instructions* 1/2” TEE Copper Pipe:  1. CAUTION: Turn off water supply. 2. Clean pipe, fittings and valve with sandpaper or wire brush. 3. Apply a thin layer of flux to all surfaces to be soldered. 4.
  • Page 6 Model 1000 Humidifier Installation Manual Installing The Control, Cont. ON-OFF HUMIDIFIER SWITCH 120v. OUTLET 115v. ON-OFF HUMIDIFIER (HOT) 60CY. SWITCH 120v. OUTLET FURNACE 115v. FIELD SUPPLIED HUMIDISTAT (HOT) CONTROL BOARD RELAY 24V COIL, N.O. 60CY. YELLOW WIRES 24V. FROM HUMIDIFIER 60CY.
  • Page 7: Final Steps Of Installation

    Model 1000 Humidifier Installation Manual Final Steps Of Installation 7. Replace evaporator pad assembly and humidifier cover. CAUTION: To prevent possible injury, ensure cover is fully  seated before continuing to next step. Insert low voltage six connector wiring harness from cover into chassis solenoid harness.
  • Page 8: Maintenance

    Model 1000 Humidifier Installation Manual Maintenance Your humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried out at the end of each heating season: 1. Turn off the water supply and electrical power to the humidifier. 2.
  • Page 9: Humidifier Chassis Cut Out

    12-1/8” Humidifier Chassis with plenum cut out shown as dashed lines Inside Your Box Model 1000A (GFI#5730) includes: Humidifier components: GA19 Vapor pad, Solenoid Assembly Accessories: GFX3 Automatic Digital Humidistat, Code Valve, Saddle Valve Model 1000M (GFI#5735) includes: Humidifier Components: GA19 Vapor Pad, Solenoid Assembly, Relay Circuit Board Accessories: MHX3C Manual Humidistat, Saddle Valve www.generalfilters.com...
  • Page 10: Troubleshooting

    • Verify water supply is on. • Check for voltage at the solenoid valve. Voltage should be 24VAC. • Verify wiring of humidifier and humidistat. • Contact licensed GeneralAire contractor to verify voltage in and out of the relay board, and replace if necessary. ®...
  • Page 11 5. Dry air can cause harm to expensive musical instruments like pianos and violins. 6. Dry air causes gaps in window & door frames, letting cold outdoor air in; causing you to turn up the heat and increasing your heating bills! Controlled humidity from the GeneralAire Humidifier allows you the ®...
  • Page 12: Limited Warranty

    Model 1000 Humidifier Installation Manual Limited Warranty What is Covered • Ten Years: The 1000 Humidifier is warranted by General Filters, Inc. (“Company”) for a period of ten (10) years from the date of the original installation, when installed in residential applications only (“Limited Warranty Period”). •...
  • Page 13 SÉRIE 1000 HUMIDIFICATEUR À QualitØ de l air frais intØrieur INSTALLATEUR : VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE ALIMENTATION CONTINUE FOIS L’INSTALLATION TERMINÉE. LAISSER LES DIRECTIVES POUR UNE INSTALLATION SUR LA D’INSTALLATION AU PROPRIÉTAIRE DE LA MAISON. SURFACE VERTICALE DU PLÉNUM PRÉCAUTION : L’installateur doit être un technicien qualifié...
  • Page 14 HUMIDISTAT ÉLECTRONIQUE GFX3 HUMIDISTAT MANUEL MHX3 DÉTECTEUR DE TEMPÉRATURE EXTÉRIEURE (NON UTILISÉ EN MODE MANUEL) FILS DE COMMANDE DE L’HUMIDIFICATEUR (FILS JAUNES) SORTIE DE 24 V DE L’HUMIDIFICATEUR (FILS ROUGES) OU PLAQUE DE MONTAGE SUR CONDUIT STANDARD AUX PLAQUE DE MONTAGE 727-58 TRANSFORMATEUR DE 24 V AVEC ALIMENTATION CONSTANTE É.-U., ACCESSOIRE EN OPTION MURAL STANDARD AU...
  • Page 15: Liste Des Pièces Pour L'humidificateur

    LISTE DES PIÈCES POUR L’HUMIDIFICATEUR 900-9 GICLEUR 900-40 RAIL DU TAMPON 900-10 BUSE GA19 TAMPON D’ÉVAPORATION 900-15 GOULOTTE DU DISTRIBUTEUR GA4247 PALE DE VENTILATEUR GA4237 MOTEUR 900-71 PLAQUE SIGNALÉTIQUE 1000-11 FAISCEAU - CARTE DE CIRCUITS IMPRIMÉS 900-14 BAC DE RÉCUPÉRATION GA4238 ENSEMBLE DU RELAIS 1137-31 CORDON D’ALIMENTATION GA4231 ORIFICE - JAUNE...
  • Page 16: Caractéristiques De L'humidificateur Elite 1000

    CARACTÉRISTIQUES DE L’HUMIDIFICATEUR ELITE 1000 Performance d’humidité prévue selon la superficie en mètres carrés/pieds carrés et le type de construction Moyen (0,50 CAH) Élevé (0,30 CAH) Nº de modèle Faible (0,75 CAH) Elite 570 111 m /1200 pi 186 m /2000 pi 74 m /800 pi...

Ce manuel est également adapté pour:

1000m57305735

Table des Matières