E Backwall to unit
F Sidewall to flue
PARALLEL
Sidewall to top
G
edge of unit
H Backwall to flue
Adjacent wall to
CORNER
J
unit
ALCOVE
K Alcove depth
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME/TRANSPORTABLE
BUILDING)
Depending
on
your
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home/transportable
building. You can purchase the 69FAK through your
heater dealer. Installation instructions are supplied
with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT
CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE,
AS WELL AS, OTHER UNFORESEEABLE ISSUES.
© 2024 United States Stove Company
K
9.5"
241 mm
13"
330 mm
8"
203 mm
3"
76.2 mm
8"
203 mm
36"
914 mm
(OPTIONAL, UNLESS
location
and
home
INSTALLATION
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the
floor.
Fresh Air
WARNING! DO NOT INSTALL IN SLEEPING
CAUTION!
THE
OF
THE
MOBILE
BUILDING FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WHEN
INSTALLED
TRANSPORTABLE
MUST BE GROUNDED DIRECTLY TO THE STEEL
CHASSIS AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements, mobile home/transportable building
installations must meet the following requirements:
• This stove must be securely fastened to the floor
of the mobile home/transportable building using
two 1/4" lag bolts that are long enough to go
through both a hearth pad, if used, and the floor
of the home.
• The heater must be electrically grounded to the
steel chassis of the mobile home/transportable
building with 8 GA copper wire using a serrated
or star washer to penetrate paint or protective
coating to ensure grounding.
• Vent must be 3 or 4-inch "PL" Vent and must
extend a minimum or 36" (914 mm) above the roof
line of the mobile home/transportable building
and must be installed using a certified ceiling fire
stop and rain cap.
• When moving your mobile home/transportable
building, all exterior venting must be removed
while the mobile home/transportable building is
being relocated. After relocation, all venting must
be reinstalled and securely fastened.
8
Exhaust
Pipe
Intake
ROOM.
STRUCTURAL
INTEGRITY
HOME/TRANSPORTABLE
IN
A
MOBILE
HOME/
BUILDING,
THE
STOVE