Télécharger Imprimer la page
United States Stove Company Ashley AP5622-W Manuel D'instructions Et D'utilisation Du Propriétaire
United States Stove Company Ashley AP5622-W Manuel D'instructions Et D'utilisation Du Propriétaire

United States Stove Company Ashley AP5622-W Manuel D'instructions Et D'utilisation Du Propriétaire

Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
AP5622-W
Report Number: F22-782
Certified to ASTM E1509-2022 and CAN/ULC
S627:2023; Complies to CAN ICES-3(B)/NMB-3(B);
Contains IC:23243-WBR1DIPEX
Mobile Home / Transportable Building Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Could Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
854000F-1904N
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour United States Stove Company Ashley AP5622-W

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 Your pellet stove has been safety tested and listed to ASTM E1509-2022 and CAN/ULC S627:2023. This manual describes the installation and operation of the Ashley AP5622-W pellet stove. This heater meets the 2020 U.S. Environmental Protection Agency’s emission limits for wood-heaters sold after May 15, 2020. Under specific EPA test conditions burning wood pellet fuel this heater has been shown to deliver heat at a rate of 13,640 to 32,591 Btu/hr.
  • Page 3 Signed: ___________________________________ Print Name: ______________________________ Date: _____________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2024 United States Stove Company...
  • Page 4 5 Pin Main Wiring Harness. Connect the 4 Pin Wiring Harness to the bottom left- hand corner of the control panel. 5 Pin Main Wiring Harness 4 Pin Fuel Sensor 7 Pin Com Cable © 2024 United States Stove Company...
  • Page 5 INSTALLATION DAMPER HANDLE INSTALLATION DOOR HANDLE INSTALLATION Twist the damper knob clockwise onto the damper Screw the spring handle onto the handle rod. rod. © 2024 United States Stove Company...
  • Page 6 THE HEATER. DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD Your heater should be installed by a qualified NFI UNDER FURNITURE. (US) or WETT (Canada) technician. To find the nearest qualified installer, go to: https://nficertified.org, https://www.wettinc.ca/ © 2024 United States Stove Company...
  • Page 7 1” (26 mm) behind the stove. Floor protection must extend under and 2” (51 mm) to each side of the chimney tee for an interior vertical installation. A Floor Protector of 1” (26 mm) thick is recommended for this installation. © 2024 United States Stove Company...
  • Page 8 • When moving your mobile home/transportable building, all exterior venting must be removed while the mobile home/transportable building is being relocated. After relocation, all venting must be reinstalled and securely fastened. © 2024 United States Stove Company...
  • Page 9 Installation MUST include at least 3-feet of vertical cleaning of the exhaust system. 90-degree elbows pipe outside the home. This will create some natural accumulate fly ash and soot thereby reducing © 2024 United States Stove Company...
  • Page 10 B. Minimum 1-foot (0.3m) clearance above any • ONLY APPROVED MATERIAL door or window that opens. INSTALLATION, FAILURE TO DO SO MAY RESULT IN PROPERTY DAMAGE, BODILY C. Minimum 3-foot (0.91m) clearance from any INJURY, OR EVEN DEATH. adjacent building. © 2024 United States Stove Company...
  • Page 11 Once outside the structure, a 3” (76 mm) wall thimble and around the vent pipe with clearance should be maintained from the outside high temperature silicone sealant. wall and a clean out tee should be placed on the © 2024 United States Stove Company...
  • Page 12 ATTEMPTING THIS INSTALL. MAKE SURE TO KEEP IN MIND YOUR UNIT’S CLEARANCE 3” to 6” Pipe REQUIREMENTS. Adapter TO STOVE Mark the area and then cut the wall for vent 3” PL Vent Clean Out Tee installation if needed. © 2024 United States Stove Company...
  • Page 13 ON/OFF HEAT MODE sequence. The fuel feed system will stop pulling (POWER) RANGE fuel from the hopper and, once the fire goes out and the heater cools down, the fans will stop running. © 2024 United States Stove Company...
  • Page 14 We cannot accept ATTENTION: responsibility for damage due to poor quality THIS APPLIANCE IS DESIGNED FOR THE USE pellet. OF PELLETIZED FUEL THAT MEET OR EXCEED THE STANDARD SET BY THE PELLET FUEL INSTITUTE (PFI). © 2024 United States Stove Company...
  • Page 15 If the fire doesn’t start in 12 minutes, press “On/Off”, closed. If the door is opened while the stove is in wait a few minutes, clear the burn pot, and start the operation it must be closed within 30 seconds or procedure again. © 2024 United States Stove Company...
  • Page 16 A. To recognize an overheat situation in the stove running all lights on the display will go out and the and shut down the fuel feed or auger system. two digit display will show “E3” © 2024 United States Stove Company...
  • Page 17 This should be done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove does not seem to be burning properly. © 2024 United States Stove Company...
  • Page 18 • Enter the 6 digit verification code that was sent to the previously entered email address. • Provide access to the two permissions requested. • Allow notifications through the phones settings. • The app is ready to add the unit. © 2024 United States Stove Company...
  • Page 19 The app and unit are now ready for use. Device Select Device Name & Screen Device Sharing Settings Current Room Temperature Temperature Adjuster Stove Setting Decrease Increase Temperature Temperature Setpoint Setpoint Mode Power ON/OFF Heat Range © 2024 United States Stove Company...
  • Page 20 Burning wood naturally produces smoke and be removed to reduce the risk of a chimney fire. carbon monoxide(CO) emissions. CO is a poisonous Inspect the system at the stove connection and gas when exposed to elevated concentrations © 2024 United States Stove Company...
  • Page 21 000 steel wool and water to if your stove is in a high humidity area. The exhaust clean the glass. DO NOT use abrasive cleaners. DO system should be thoroughly cleaned. © 2024 United States Stove Company...
  • Page 22 Chamber Ashes Check Empty Interior Vacuumed Chambers Combustion Vacuumed Blower Blades / Brushed Convection Vacuumed Blower Impeller / Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper (end of Empty & season) Vacuumed © 2024 United States Stove Company...
  • Page 23 200 mm (8 in) beyond the appliance on other DO NOT INSTALL IN AN ALCOVE sides, shall be protected by a continuous, durable, DO NOT INSTALL IN ANY FIREPLACE © 2024 United States Stove Company...
  • Page 24 High Limit Switch is malfunctioning. switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2024 United States Stove Company...
  • Page 25 (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2024 United States Stove Company...
  • Page 26 The control board is not sending power to There should be a 5-volt (approximately) current going the POF thermodisc or other auger system to the POF thermodisc after the stove has been on for 10 components. minutes. © 2024 United States Stove Company...
  • Page 27 Check to see if the sensor is unplugged. If the sensor is not when turned on unplugged then the sensor is damaged or has a short. If the sensor is damaged or has a short it will need to be replaced. © 2024 United States Stove Company...
  • Page 28 Circuit board malfunction. the control board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2024 United States Stove Company...
  • Page 29 If there is not a full Bad control board. current going to the auger motor when the fuel feed light is on, you have a bad control board. © 2024 United States Stove Company...
  • Page 30 You might also want to try a brand AT A VERY FAST RATE Only) that is made from a different type of wood (softwood vs. hardwood). Different woods have different characteristics when being burned. © 2024 United States Stove Company...
  • Page 31                 ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN. CORRECT WRONG © 2024 United States Stove Company...
  • Page 32 Drive Motor 80866 (1.5 RPM CCW) IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 United States Stove Company...
  • Page 33 Engineer Name: _______________________________ Engineer Name: _______________________________ License No.: ____________________________________ License No.: ____________________________________ Company: _____________________________________ Company: _____________________________________ Telephone No.: _________________________________ Telephone No.: _________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: _______________________________ Items Replaced: _______________________________ © 2024 United States Stove Company...
  • Page 34 NOTES © 2024 United States Stove Company...