Water Connection - Solarjet SOL-M Manuel D'utilisation

Masquer les pouces Voir aussi pour SOL-M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 - INSTALLATION INSTRUCTIONS
Fig. 2.4-2
2.5

WATER CONNECTION

Section tubes
For models SNPD the diameter of the tubes is
recommended 1/2 "; if the shower installation is a
long way from the feed point, a diameter of 3/4 tube"
is recommended.
For the M model instead of 3/4 ".
With regard to the P3-P2-D models:
For a total and complete internal cleaning of the tank
it is necessary, before you have attached the kit
showerhead:
make the water connection
completely fill the tank
drain the water from the upper sleeve for 5
minutes
attach the supplied showerhead
The
operations
relating
disconnection water attack and those relating to the
replacement of the shower head and the foot -
washing tap require that the fittings fixed to the
shower body are necessarily held in place by means
of a wrench in order to avoid going to loosen the
seal between body shower and fitting itself.
Fig. 2.4-3
Fig. 2.4-4
Fig. 2.4-5
to
the
connection
/
Fig. 2.5-1
Mounting check valve (SOL MSN)
The safety valve and check valve, provided only with
the MSN models, must be installed in the cold water
inlet with the arrow pointing towards the device (1), no
interception between valve and shower (2).
The black lever (3) on the safety valve serves for
emptying the shower.
Fig. 2.5-1
Fig. 2.5-3
water Parameters
The appliance will last longer if they are met, as
provided
for
by
Decree.
(implementation of Directive 98/83 / EC relating to the
quality of water intended for human consumption), the
following parameters:
total hardness: between 15 and 50 ° F (in particular
for water treatment has undergone a softening or
desalination)
chlorides: 25 mg / l (maximum value 200 mg / l)
pH: between 6.5 and 9.5
conductivity: 400 mS / cm (maximum value 2500
mS / cm)
Where water with parameters do not conform to the
above, the warranty will automatically lapse.
The
model
M, in particular, is equipped with a
magnesium
anode
for
currents and every 8-12 months is mandatory its
replacement.
To replace it do the following:
remove the black cover (28) located in the upper
part
unscrew the cap (17)
remove the nut (27) and the washer (5)
unscrew the old anode (9) and replace it with the
new one
reposition washer (5) and nut (27)
screw the cap (17)
reposition the black cover (28)
Fig. 2.5-2
02/02/2001,
n.
protection
against
galvanic
Fig. 2.5-4
31