2 - INSTRUCTIONS TO THE INSTALLER
2.1
RECOMMENDATIONS FOR the INSTALLATION
During
the installation
participations
of
maintenance,
the contained instructions in the manual present.
The modifications of the connections of every kind and
the lacked respect the present instructions provoke the
immediate decay of the guarantee.
To use reciprocations originates supplied them from the
constructor.
2.2
PACKING
The apparatus comes delivered packed in one scato it
of cardboard with opportune protections.
Inside containing envelope is present one the present
booklet and the certificate of guarantee.
DIMENSIONS I PACK
M
48x49x214 cm
S
35x35x224 cm
N
35x35x224 cm
P3
35x35x224 cm
P2
25x25x224 cm
And
25x25x224 cm
C
35x35x224 cm
2.3
DIMENSIONING
For
being
able
to
establish
proporzionato and not sottodimensionato, it must hold
account of the requirements and some sagacities during
the installation.
We bring back here of continuation some useful
councils:
to posizionare the shower in zone always exposed in
sunlight and not ombreggiata
in the arc of one day of optimal insolation, the model
M it is in a position to supplying until 240 liters of
warm water to temperature of I use, i models S-N
beyond 120 liters, model P3 approximately 50
liters, [[il]] model P2 approximately 35 liters and i
modelli And- C approximately 40 liters
2.4
POSITIONING Of the APPARATUS
The solar shower to I accumulate must be installed so
that always it is exposed to the solar beams and date
its shape circular, succeeds to pick up the same ones
from every position; in any case the ideal guideline of
the solar shower is towards SOUTH.
IMPORTANTAnd
The shower goes only mounted and exclusively in
or
in
case
of
to carefully observe
WEIGHT
WITH I
PACK
65 Kg
15 Kg
12 Kg
10 Kg
7 Kg
7 Kg
7 Kg
if
the
system
very
Fig. 2.4-1
vertical position in order to favor of the stability.
Relatively to i models S-P, in order to optimize the
rendering the apparatus is slanted leggermente in such
way
that
the
beams
regarding the body of the shower.
In fact, the inclination of the same one favors the
stratification of the water and, since the withdrawal of
money happens in the high part, has the best one uses
than all the warm water.
IMPORTANTAnd
Models M-S-N preview a covering in meth-acrylate
and are therefore necessary lend much attention
during their movimentazione.
In particular it must proceed to the movement of the
showers raising them solo from the base or the top
avoiding to seize the outer cover in meth-acrylate (you
see
Fig. 2.4-2, Fig. 2.4-3, Fig. 2.4-4, Fig. 2.4-5).
This in how much, being a material much fragile one,
would run the risk to procurare breaches or leaks of the
same meth-acrylate that would go to inficiare the good
operation and the yield of the apparatus.
Fig. 2.4-2
2.5
HYDRAULIC CONNECTION
Section tubes
For i models S-N-P-E- C the diameter of the tubes
advised is 1/2"; sand installazione of the shower
comes made much far one from the feeding point, is
advised to a diameter tubes of 3/4".
For model M it is instead from 3/4 ".
Relatively to the models P3-P2- C:
For one total and completes pulizia inner of the tank
turns out necessary, before having fixed the
soffione to equipment:
•
to realize the water connection
•
to fill up the tank completely
•
to
make to
advanced muff for 5 minuteren
16
are
perpendicular
fuoriuscire the
water
possible
Fig. 2.4-3
Fig. 2.4-4
Fig. 2.4-5
from
the