Symbols in the Display
Temperature or Error code display for upper/left zone.
Temperature or Error code display for lower/right
zone. Compressor is ON
Heater is ON
Defrosting mode
Dynamic Climate mode
Eco Demo mode
The interior light is in Showcase mode
Warning
Audible tones signal
Child lock is activated
Multi-key Function
To perform the multi-key function, lightly touch and hold the first ke , then touch the rest key for at
least 5 seconds and then release all the keys.
Child Lock
(Only for models with outside controls) If in 2 minutes or longer without touching any key, the child
lock will be activated automatically. To remove the lock, press the UP and DOWN keys at the same
time for at least 5 seconds until the symbol
Setting the Temperature Control
The unit has two separate temperature zones. The temperature of both zones can be set between
5ºC and 20ºC (41ºF and 68ºF). It can be used as a wine maturing cabinet or a wine
serving cabinet. For maturing wine, the recommended temperature setting ranges of both zones
should be between 11ºC and 14ºC (52ºF and 57ºF). For serving wine, the recommended
temperature setting range of UPPER/LEFT zone should be between 5ºC and 10ºC (41ºF and
50ºF) which is ideal for serving champagne & white wine and the recommended temperature
setting range of LOWER/RIGHT zone should be between 15ºC and 20ºC (58ºF and 68ºF)
which is ideal for serving red wine.
When the unit is plugged in for the first time, the unit will power up automatically to the preset
defaults. The preset temperature at the factory for UPPER/LEFT temperature zone is 8ºC (46ºF )
and for LOWER/RIGHT temperature zone is 12ºC (54ºF ).
Touch the Setting Selector
use the UP and DOWN keys to set the internal temperature as required. When you touch either
key at the first time, the display will show the last temperature set previously.
IMPORTANT: For non-twin wine conditioning system, the temperature set for the LOWER
temperature zone must always be just as high as or higher than that in the UPPER temperature
zone.
is go out.
until the temperature you want to set is flashing. Then you can
EN-76