The machine asks for the drip
tray to be emptied although it is
not full.
The appliance asks to be
unplugged and plugged back in
again.
The machine does not request
descaling.
Some ground coffee has found
its way into the drip tray.
The milk or water is not flowing
correctly into the cup(s).
There are traces of milk in an
Americano or a Hot water.
There is water underneath the
appliance.
When you turn off the appliance,
warm water flows out of the
coffee outlets and the One Touch
Cappuccino block.
After emptying the coffee
grounds collector, the warning
message is still displayed on the
screen.
The coffee dispenses too slowly.
The water tank has been filled,
but the warning message is still
displayed on the screen.
The coffee fineness knob is
difficult to turn.
The espresso or coffee is not hot
enough.
30
The machine is programmed to ask for the drip tray to be emptied after a certain
number of coffees despite any intermediate emptying operations that you may
complete.
Unplug the appliance for 20 seconds, remove the Claris Aqua Filter System
cartridge if necessary, then plug it back in again.
If the error continues, contact the KRUPS Customer Service team.
The descaling cycle is requested after the steam circuit has been used a
significant number of times.
A small amount of ground coffee may settle in the drip tray. The machine is
designed to evacuate any excess ground coffee so that the percolation zone
remains clean.
Check that the One Touch Cappuccino block is correctly positioned.
Complete a milk rinsing cycle or dismantle and clean the one touch cappuccino
accessory before running the preparation.
Before removing the water tank, wait for 15 seconds after the coffee has
finished flowing so that the appliance finishes its cycle properly. Check that the
drip tray is correctly positioned on the machine; it should always be in place,
even when the appliance is not in use. Check that the drip tray is not full.
The drip tray should not be removed during a cycle.
According to the type of recipe prepared, the machine may run an automatic
rinsing cycle when it is turned off. This cycle lasts only a few seconds and stops
automatically.
Correctly replace the coffee grounds collector and follow the instructions on
the screen.
Wait at least 5 seconds before replacing them.
Turn the 'fineness of grind' adjustment dial to the right to make the ground
coffee coarser (according to the type of coffee used).
Run one or several rinsing cycles.
Run a machine clean (see "Automatic machine cleaning programs p.28).
Change the Claris Aqua Filter System cartridge (see "Installing the filter") p. 23).
Check that the tank is installed correctly on the device.
The float at the bottom of the tank should move freely. Check and unblock the
float if necessary.
Only change the grinder setting when it is running.
Run a coffee circuit rinsing cycle before preparing your coffee.
Increase the coffee temperature in the Settings menu. Warm the cup by rinsing
it with hot water before making the drink.