Télécharger Imprimer la page

Aprimatic PARK 30 XT Instructions D'installation Et D'entretien page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.5 ALIGN THE ARM
Give the "START" command
to position the arm holder
horizontally
TO ALIGN THE BOOM TO THE FLOOR LINE
(HORIZONTAL POSITION) SET THE POSITION
OF THE ADJUSTABLE BOOM HOLDER
Give the "START" command
to position the arm holder
vertically
2.6 BALANCING THE ARM
Remove the lever fi xing screw
WITH MOUNTED BOOM ONLY
2. Installation
Electrically connect the control unit (see point 2.8)
Adjustable arm holder
2 x 13mm
TO SET THE BOOM IN VERTICAL
POSITION ADJUST THE OPEN LIMIT
SWITCH CAM.
Always disconnect the electricity
before attempting any work on the system.
- 13 -
Check that the bar is
in horizontal position
Opening
microswitch cam
3 mm
Check that the bar is
in vertical position
EN
24 mm

Publicité

loading