PARAMETERS TABLE
A
Water intake temperature
b
Water outlet temperature
c
Ambient air temperature
d
Setting temperature
E
Defrost auto-activation time
F
Maximum defrost duration
H
Adjustment of temperature difference for restart
J
Automatic restart
O
Antifreeze protection - low air temperature
P
Evaporator temperature to enter defrosting mode
U
Evaporator temperature to exit defrosting mode
t
Reserved - do not modify
F
OPERATION
Conditions of use
For the heat pump to operate normally, the ambient air temperature must be between
8°C and 43°C.
Recommendations prior to start-up
Before activating the heat pump, please:
Check that the unit is stable.
Control the proper functioning of your electrical installation.
Check that the hydraulic connections are tight and that there is no leakage of water.
Remove any unnecessary object or tool from around the unit.
Operation
1. Connect the unit power plug.
2. Activate the circulating pump.
3. Activate the unit's power supply protection (differential switch and circuit-breaker).
4. Activate the heat pump by pressing once on
5. Select the required temperature.
6. The heat pump's compressor will start up after a few moments.
All you have to do now is wait until the required temperature is reached.
Description
Adjustment
Factory
range
setting
-19~99°C
-19~99°C
-19~99°C
15~40°C
27°C
10~80 min
40 min
10~40 min
30 min
1~10°C
3°C
0 = OFF
1
1 = ON
0~15°C
8°C
-19°C~0°C
-3°C
1~30°C
20°C
.
Remarks
Actual data
Actual data
Actual data
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Reserved
4
45