Télécharger Imprimer la page

United States Stove US5522 Manuel D'instructions Et D'utilisation Du Propriétaire page 12

Publicité

• Do not exceed more than 4ft (1.22m) of pipe on a
horizontal run and use as few elbows as possible. If
an offset is required, it is better to install 45-degree
elbows rather than 90-degree elbows.
WARNING:
YOU MAY WANT TO LOCATE ANY UTILITIES
OR OBSTACLES INSIDE THE WALL BEFORE
ATTEMPTING
THIS
TO KEEP IN MIND YOUR UNIT'S CLEARANCE
REQUIREMENTS.
1.
Mark the area and then cut the wall for vent
installation if needed.
2. Install the wall thimble as specified by the
manufacturer (wall thimble sold separately)
3. Install venting.
VENTING YOUR PELLET STOVE INTO AN
EXISTING CLASS A 6" CHIMNEY SYSTEM
IMPORTANT:
IF YOU ARE INSTALLING YOUR PELLET STOVE AS
A REPLACEMENT TO AN EXISTING WOOD STOVE,
YOU CAN INSTALL YOUR PELLET STOVE USING
THE EXISTING CLASS A 6" VENTING SYSTEM.
1.
You must have the existing chimney system cleaned
and/or inspected by a qualified chimney sweep before
proceeding with the installation of your pellet stove.
2. To the right is an example of an installation using part
number 860001, 3-6" transition into 6" connector
pipe (the illustration is only an example). Please
conform to any local building codes or regulations
having jurisdiction before you have a qualified
installer proceed with this installation.
© 2024 United States Stove Company
INSTALL.
MAKE
SURE
Ceiling
Support
TO STOVE
12
INSTALLATION
Existing Class 'A'
6" Chimney System
Support
Bracket
3" to 6" Pipe
Adapter
3" PL Vent
Clean Out Tee

Publicité