Télécharger Imprimer la page

Ferroli 0RGE01XA Notice Pour L'installation, L'utilisation Et L'entretien page 56

Chaudière à condensation à très haut rendement pressurisée en acier

Publicité

Les langues disponibles

Les langues disponibles

MODEL: TP3 COND 150 (OIL)
Trademark: FERROLI
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
MODEL: TP3 COND 150 (GAS)
Trademark: FERROLI
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
56
en
ErP product fiche
ErP product fiche
cod. 30902850 - Rev. 04 - 10/2019
TP3 COND 65 ÷ 1000
Symbol
Unit
Value
137
Pn
kW
η
93
s
%
137,3
P4
kW
P1
kW
44,2
η
90,9
%
4
η
97,9
%
1
0,195
elmax
kW
0,170
elmin
kW
PSB
kW
0,003
0,990
Pstby
kW
Pign
kW
0,000
QHE
GJ
426
68
LWA
dB
NOx
mg/kWh
128
Symbol
Unit
Value
137
Pn
kW
η
s
%
92
137,3
P4
kW
45,4
P1
kW
η
87,4
%
4
η
96,8
%
1
0,230
elmax
kW
0,110
elmin
kW
PSB
kW
0,003
0,990
Pstby
kW
Pign
kW
0,000
QHE
GJ
432
66
LWA
dB
63
NOx
mg/kWh

Publicité

loading

Ce manuel est également adapté pour:

Tp3 cond 100Tp3 cond 150Tp3 cond 230Tp3 cond 370Tp3 cond 500Tp3 cond 650 ... Afficher tout