Pre-Installation (continued)
ELECTRICAL REQUIREMENTS
WARNING:
□ Plug into a grounded 3-prong outlet.
□ Do not remove ground prong.
□ Do not use an adapter.
□ Do not use an extension cord.
□ Failure to follow these instructions can result in death, fire, or electrical shock.
Recommended Grounding Method
This portable air conditioner must be grounded. This portable air conditioner is equipped with a power supply cord with a three-prong
grounding plug. The cord must be plugged into a properly grounded three-prong outlet, grounded in accordance with all local codes and
ordinances. If a properly grounded outlet is not available, it is the customer's responsibility to have a properly grounded three-prong outlet
installed by a qualified electrician.
Customer's Responsibility
□ To contact a qualified electrical electrician.
□ To assure that the electrical installation is adequate and conforms to the national electrical code. ANSI/NFPA 70-last edition, and all
local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
www.nfpa.org
Wiring Requirement
115V (103.5 min. to 126.5 Max.); Minimum 13A time-delay fuse or circuit breaker
Power Supply Cord
NOTE: Your air conditioner's device may differ from the one shown. This room air conditioner is equipped with a power supply cord required
by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect
leakage current and power will be disconnected in a fraction of a second.
To test your power supply cord:
1. Plug power supply cord into a grounded 3-prong outlet.
2. Press RESET (2) (on some devices, a green light will turn on).
3. Press TEST (1) (listen for click; Reset button will trip, and on some devices,
a green light will turn off).
4. Press and release RESET (2) (listen for click; Reset button will latch, and on some
devices, a green light will turn on). The power supply cord is ready for operation.
NOTE:
1. The RESET button must be pushed in for proper operation.
2. The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset.
3. Do not use the power supply cord as an off/on switch. The power supply cord is designed as a protective device.
4. A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be
repaired.
5. The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.
4
2
1