MAINTENACE:
To keep your CO detector in proper working order, please follow these easy steps:
Check whether the alarm is working properly by pressing the test button every week.
Clean the CO detector with a vacuum cleaner or with a soft cloth or brush once every month to remove
excess dust.
Check whether the batteries are damaged, exhausted or corroded.
Explain to children that they should not play with the CO detector.
Ensure children are aware of the dangers of carbon monoxide poisoning.
Never use cleaning agents or other solutions to clean the CO detector.
Never use air fresheners, hair spray or other aerosols near the CO detector.
Don't paint the CO detector. Paint covers the vents preventing the sensor from detecting CO.
Never disassemble, repair or modify the product yourself; there's a high risk that it will no longer
function correctly or reliably.

BATTERY REPLACEMENT

Remove the battery cover on the back of the unit by sliding the cover off the product, you will now have
access to the batteries.
Remove the batteries from the unit and replace them with 3x new High Energy Alkaline batteries 1,5V AA -
LR6, making sure that the battery polarity matches the instructions in the battery compartment.

SENSOR REPLACEMENT:

The sensor has a lifetime of 10 years. After 10 years you need to replace the complete product, the sensor
itself is not exchangeable.
If the yellow LED illuminates within these 10 years, even though you've reconnected or replaced the
batteries, please refer to the paragraphs Reason for sensor fault and Sensor fault caused by chemical
gases.
If the red LED switches on, the yellow "FAULT" LED illuminates 3x and 3 beep tones are emitted while
appears in the display, the entire product should be replaced.
SPECIFICATIONS:
Power supply:
Sensitivity and time:
standby consumption:
consumption at alarm:
Sound pressure at alarm:
Environmental conditions
during use:
Type:

DECLARATION OF CONFORMITY

The declaration of conformity is available on the website http://DOC.hesdo.com/COA26-DOC.pdf
3 x LR6, 1,5V AA high energy Alkaline batteries
33ppm, alarm is not activated within 120 minutes
50ppm, alarm is activated within 60~90 minutes
100ppm, alarm is activated within 10~40 minutes
300ppm, alarm is activated within 3 minutes
<35µA
<85mA
>85dB (3m distance)
0~45°C, 0~90% humidity.
Type B (unchecked output)
42