MAINTENACE:
To keep your CO detector in proper working order, please follow these easy steps:
•
Check whether the alarm is working properly by pressing the test button every week.
•
Clean the CO detector with a vacuum cleaner or with a soft cloth or brush once every month
to remove excess dust.
•
Check whether the batteries are damaged, exhausted or corroded.
•
Explain to children that they should not play with the CO detector.
•
Ensure children are aware of the dangers of carbon monoxide poisoning.
•
Never use cleaning agents or other solutions to clean the CO detector.
•
Never use air fresheners, hair spray or other aerosols near the CO detector.
•
Don't paint the CO detector. Paint covers the vents preventing the sensor from detecting CO.
•
Never disassemble, repair or modify the product yourself; there's a high risk that it will no
longer function correctly or reliably.
BATTERY REPLACEMENT
To replace the battery, slide the backplate down a half centimeter and then remove it to see the
battery compartment.
SENSOR REPLACEMENT:
The sensor has a lifespan of 7 years. After 7 years you should replace the entire product because
the sensor cannot be replaced.
If the yellow LED illuminates within these 7 years, even though you've reconnected or replaced
the batteries, please refer to the paragraphs Reason for sensor fault and Sensor fault caused by
chemical gases.
If the red LED switches on, the yellow "FAULT" LED illuminates 2x and 2 beep tones are emitted
while
appears in the display, the entire product should be replaced.
SPECIFICATIONS:
Power supply:
3 x LR6, 1,5V AA high energy Alkaline batteries
Sensitivity and time:
33ppm, alarm is not activated within 120 minutes
55ppm, alarm is activated within 60~90 minutes
110ppm, alarm is activated within 10~40 minutes
330ppm, alarm is activated within 3 minutes
standby consumption:
80µA ± 10µA
consumption at alarm:
45-75mA
Sound pressure at alarm: >85dB (1m distance)
Environmental conditions: 0~45°C, 0~90% humidity.
Screen display:
25-550PPM ±10% deviation
Temperature display:
-15°C - 50°C ±1°C (Only shown when the CO is below 25PPM)
Dimensions:
90x120x40mm
Weight:
220g
Type:
Type B (unchecked output)
DECLARATION OF CONFORMITY
The declaration of conformity is available on the website http://DOC.hesdo.com/COA-26-DOC.pdf