Using buttons in an easy way you can control work of controler, move through parameters menu and
change them.
Parameters setting:
Thanks to parameters you can adjust work of controller to own needs, so that it would optimally
control work of controller. There are nine parameters available and additional selection of controller's
work mode.
After entering settings menu with button
(name of parameter displayed on the display). After choosing parameter we enter it setting with
button
and once again using buttons
pushing button
. At any moment we can leave parameters menu, as well as parameter setting by
pushing button
.
Go back to normal work takes place also in case of no activity (not pushing buttons) for over ten
seconds.
Parameters description:
Repetition time is interval of time when controller checks condition if current temperature is
higher or lower from given (parameter t1). If it is higher then the throttle is closed by one step,
if it is lower then it is opened. This parameter should be choosen experimentally according to
rule – that if temperature changes slowly we choose shorter repetition time, if temperature
changes too quickly repetition time should be longer. At optimally choosen parameter
given state we have small temperature oscillations
Temperature of work is temperature, which controller by changing throttle setting,will
try to maintain.
Temeperature of CO pump turning on/off is a parameter deciding about point of CO pump
switching. After exceeding temperature
-
and waiting time
Temperature on/off of the fan or other device. Its value determines the point on/off output
marked with
Temperature of alarm after exceding value of set temperature in this parameter, the controller
begins to signalize this situation with alarm sound signal and symbol of triple exclamation
mark displayed alternately with temperature value.
Parameter specifies the position of the throttle after going into standby.
Hysteresis on/off pump and fan
Pump and fan running time in minutes.
parameter specifies the time in minutes, this is the time that must elapse after falling below
tempereature
The „O" parameter means that the driver will not automatically go into standby.
parameter indicates, for which outputs is the function of postseason start pumps, this is the off
heating season starting pump, every week for 1 minute.
„0" parameter indicates that the function is off for both outputs.
„1" parameter indicates that the function is active only for the CO pump.
„2" parameter indicates that the function is active only for the additional output.
„3" parameter indicates active function for both outputs.
Parameter specifies the minimum throttle position when operating in automatic mode.
the pum is turned off.
symbol, in the same way as in the case of
C.
o
-
C and
-
o
we choose with buttons
and
we choose value of parameter. We confirm it by
.
pump turns on, and after drop of the temperature
, after which the driver goes into standby.
and
proper parameter
value and CO pump.
, in