Télécharger Imprimer la page

Napoleon Woodland NEFI27H Instructions D'installation Et D'opération page 10

Masquer les pouces Voir aussi pour Woodland NEFI27H:

Publicité

Les langues disponibles

Les langues disponibles

10
3.2
HARD WIRING INSTALLATION
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
EN
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
HARD WIRING CONNECTION
If it is necessary to hard wire, a qualified electrician must remove the cord connection, and wire directly to the
household wiring. The wire and power supply breaker must be rated for 120V and a minimum of 15 Amps.
This log set must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 3 wires from the fireplace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
Remove the securing screw from the electrical cover plate, located on the rear of the log set.
A.
Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.
B.
C.
Separate the black, white and green wires that have the wire nuts on them.
Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of the
D.
power supply. Connect the white wire from the unit to the white (neutral) wire from the power
supply. Connect the green wire to the ground wire.
Resecure the cover plate.
E.
F
J
I
U
R
N
E
C
P
T
L
I
A
O
C
N
E
W415-1461 / C / 08.04.16
(L1)
BLACK
WHITE
(N)
GREEN
(G)
WIRE NUT
WARNING
!
NOTE: It is recommended to
secure the log set after hard
wiring, refer to "SECURING
THE LOG SET" section.
White, Green and
Black wires:
Connect to 120V
power supply.
WHITE
BLACK
GREEN
NOTE: Leave enough
wire so that the log
S
P
U
set can be removed
BLACK
O
P
from the enclosure
W
P
WHITE
E
without disconnecting
L
R
the power supply.
Y
GREEN

Publicité