2) Add the solar control. While the parameter 14= 1, solar energy control is available. The
terminal "TO PUMP" is connected solar energy water pump, "FS" is connected the flow switch of
solar water circuit, "SOLAR SENSOR" is testing the temp of solar thermal collector.
3) Electrical anod anti-corrosion system is maitanance free system and mainly consists of
controller and titanium electrode, which makes sure the inner wall of the stainless steel tank is
always protected against corrosion efficiently.
4) When the controller reports the related fault of the electronic anode, please contact the local
service provider for on-site repair in time. In addition, the system will prohibit auxiliary electrical
heater work under the fault state, and the heat pump is only allowed to work for 3 days, after that
the whole unit will be locked and cannot continue to work。
Electronic Protection Anode Review
- Check periodically by the authorized SAT that the electronic protection anode works correctly.
Schematic overview of the water and refrigeration circuit
Choose the suitable unit
Please refer to the table below to choose the suitable unit.
Family members
2 ~ 3 people
4 ~ 5 people
6~ 7 people
More than 8 people
Note:
The table is just for reference.
Tank capacity
200L
250L
300L
500L
53