Step 5: Misting Testing
a. Full fill the water tank with clean water, and cover the tank lid.
b. Keep the ball valve from "on " to "off ", and turn power on. Turn the switch knob, and
check if the motor and blade operate normally.
c. Press misting button, run misting motor and water pump, and check if the misting motor,
misting plate and water pump operate smoothly.
d. Turn ball valve from " on" to "off", and observe the misting adjustment function.
e. Press the button of the UV lamp switch to turn on the UV sterilization device,
the ballast indicator is green color.
f. Adjust the plastic screw, and check if the oscillation function work smoothly.
Product Dimension
DIAGRAM 5
Diagram 7
.
27
Speed-adjusting
switch
Securing scew
Ball valve