ERROR CODES CONTINUED
ESO2
Open circuit at temperature sensor #2
Short circuit at room temperature sensor
ESC3
ESO3
Open circuit at temperature sensor #3
TROUBLESHOOTING
SYMPTOM
Heater does not turn on.
The blower does not turn
on during Cleaning Cycle,
Feeding Cycle, or Lighting
Cycle.
The blower does not turn on
during Stabilization Cycle.
During the Lighting phase
the auger is not filling the
firepot with pellets.
During operation, besides
the Lighting phase, the
auger is not filling the firepot
with pellets.
Master Forge Wood Pellet Fire Stove
(#3)
CAUSE
Power Switch
turned off.
Power Cord
disconnected.
Fuse is blown.
This is normal.
No power in stove
or in control panel.
Mother board
disconnected.
Low Temperature
sensor is broken.
This is normal.
No fuel in Pellet
Hopper.
Auger is blocked,
jammed, or
disconnected.
1. Check wires and connection points.
2. Replace Motherboard.
1. Check wires and connection points.
2. Replace Motherboard.
1. Check wires and connection points.
2. Replace Motherboard.
SOLUTION
Turn on power switch.
1. Press power cord tightly into the heater
2. Ensure that the wall socket is delivering 120 Volts.
Replace the fuse.
There is no problem, the blower does not turn on
until the stabilization cycle.
Check the power and wires.
Make sure all terminals to mother board are
connected.
Replace the low temperature sensor.
There is no problem, the auger does not operate
during the Lighting phase.
Add Fuel to Pellet Hopper.
1. Unplug the unit so that it will not start suddenly
and then unblock the auger.
2. Check that the auger is not blocked. If it is
blocked, remove the cause of the jamming.
3. Check that the auger screw fastening the auger to
the motor is secure.