Télécharger Imprimer la page

Master Forge H30XL Instructions D'utilisation Et Manuel Du Propriétaire page 22

Publicité

Les langues disponibles

Les langues disponibles

REPLACING: HEAT EXCHANGE BLOWER
Unplug the heater. Disconnect any wiring leading to
the Heat Exchange Blower. Remove the screws holding
the mounting plate to the heater. Slowly remove
blower and replace with new one. Replace screws and
wiring.
REPLACING: EXHAUST BLOWER
Unplug the heater. Disconnect any wiring leading to
the Exhaust Blower. Remove the wing nuts holding the
Exhaust Blower plate to the blower housing. Slowly
remove blower and replace with new one. Replace
wing nuts and wiring.
Master Forge Wood Pellet Fire Stove
SAFETY COMPONENTS
1. Vacuum Pressure Switch: A safety vacuum switch is
located behind the left door, fastened to the base.
If a low pressure is created in the firebox by a leak,
opening the door to the firebox, a blocked flue, or
an unsealed ash drawer then the switch will shut
the stove off as a precaution. Error code E5 will
appear on the display panel.
2. High Limit Thermostat: A high temperature limiter
is installed on the bottom of the hopper. If this
sensor is exposed to temperatures higher than 158
degrees then the stove is shut off.
3. Vent Pipe High Temperature Thermostat: A high
temperature limiter is installed on the vent pipe.
If this sensor is exposed to temperatures higher
than 104 degrees then the circulation fan blower is
switched on.
4. Vent Pipe Low Temperature Thermostat: If the
stove cools below a minimum temperature the
stove will switch off. This may occur when the
operating procedure fails to quickly and sufficiently
heat the stove.
5. Fuse: A fuse on the rear of the device protects the
stove from power surges. See Figure 23.
Figure 23
Fuse
22
Operating Instructions and Owner's Manual

Publicité

loading