Electrical and Environmental Specifications:
Table 1. Electrical Ratings.
Operational Voltage
Flashes/minute
Maximum Operating Current, Amperes
Frequency, Hz
DC in-rush current is 1.75 A @ 24VDC for 5 msec.
AC in-rush current is 2.0 A @ 85VAC and 1.5 A @ 265VAC for .25 msec.
Table 2. Ambient Temperature ratings and operating temperature.
Hazardous Locations
Class I, Div 1,
Groups C and D
Class I, Div 2,
Groups A and B
Class II, Div 1 and 2,
Groups E, F and G
Class III
Ambient Storage Rating: -55°C to +70°C
Ambient Operating Rating: -25°C to +66°C
Installation Environmental Ratings: Type 4X, IP66, Indoor/Outdoor Use, and
Outside Type (Saltwater).
24V DC/AC
60
0.38
DC/50/60
T-Code or Maximum Temperature, °C
40°C Ambient
24 V
100 - 265 VAC
T6
T6
T6
T6
T6
T6
T6
T6
100 - 265VAC
60
0.21
50/60
55°C Ambient
24 V
100 - 265 VAC
T6
T6
T6
T5
T6
T6
T6
T6
-7-
66°C Ambient
24 V
100 - 265 VAC
T6
T6
T5
T4A
T6
T6
T6
T6