Fault
The appliance
turns on, but the
temperature is too
high/low
The appliance is
leaking water
The appliance is
unusually loud
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
Power
G608
150W
G609
150W
G610
150W
G611
230W
GD875
150W
220-
240V~
50Hz
GD876
150W
GD877
150W
GD878
230W
6
G608-G611_GD875-GD878 _ML_A5_v9_20240403.indb 6
G608-G611_GD875-GD878 _ML_A5_v9_20240403.indb 6
Probable Cause
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat
source or air flow to the condenser
is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
The drip tray is overflowing
Loose nut/screw
The appliance has not been installed
in a level or stable position
Temperature
Current
Range
1A
2°C - 8°C
5 x gastronorm 1/4
1A
2°C - 8°C
7 x gastronorm 1/4
1A
2°C - 8°C
8 x gastronorm 1/4
1.6A
2°C - 8°C
10 x gastronorm 1/4
1A
2°C - 8°C
3 x gastronorm 1/3
1 x gastronorm 1/2
1A
2°C - 8°C
5 x gastronorm 1/3
1 x gastronorm 1/2
1A
2°C - 8°C
8 x gastronorm 1/3
1.6A
2°C - 8°C
9 x gastronorm 1/3
Solution
Defrost the appliance
Clean the Condenser
Check doors are shut and seals are not
damaged
Move the appliance to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance
(if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if
applicable)
Consult a qualified Technician
Empty the drip tray (if applicable)
Check and tighten all nuts and screws
Check installation position and change if
necessary
Capacity
Refrigerant
R600a 45g
Container
R600a 45g
Container
R600a 45g
Container
R600a 45g
Container
R600a 45g
Container
Container
R600a 45g
Container
Container
R600a 45g
Container
R600a 45g
Container
Dimensions
Weight
H x W x D mm
(kg)
435 x 1200 x 380
49
435 x 1500 x 380
57
435 x 1800 x 380
65
435 x 2000 x 380
34
435 x 1200 x 380
28
435 x 1500 x 380
31
435 x 1800 x 380
35
435 x 2000 x 380
37
2024/4/3 16:59
2024/4/3 16:59

Publicité

loading

Ce manuel est également adapté pour:

G609G610G611Gd875Gd876Gd877 ... Afficher tout