11.1.2
n
Description
Code
Relay
786
Upper sensor
787
Mid-upper sensor 788
Mid-lower sensor 789
Lower sensor
78A
Low voltage
78B
Higher voltage
78C
Dry fire protec-
78D
tion
Discharge over
78E
temperature
Discharge sensor 78F
Coil sensor
790
Ambient sensor
791
Suction sensor
792
Low pressure
793
0336078_CAWH_ENNLFR_V2.0, 15-05-2024
Displayed errors
Note
For the coding of the connections, refer to the Electrical wiring diagram.
Note
Contact your service and maintenance engineer if the error persists.
Note
Each error has a code and a description.
Cause
Water temperature is sensed to be
rising when there is no water heat-
ing
Upper tank temperature sensor is
not functioning.
Mid-upper tank temperature sensor
is not functioning.
Mid-lower tank temperature sensor
is not functioning.
Lower tank temperature sensor is
not functioning.
Power supply voltage is too low.
Power supply voltage is too high.
Not enough water in tank.
Heat pump discharge temperature is
too high.
Heat pump discharge temperature
sensor is not functioning.
Coil temperature sensor is not func-
tioning.
Ambient temperature sensor is not
functioning.
Heat pump suction sensor is not
functioning.
Heat pump low pressure switch is
open.
Measure
Recycle electrical power to heater. Re-
place main control board.
Replace upper tank temperature sensor.
Replace mid-upper tank temperature sen-
sor.
Replace mid-lower tank temperature sen-
sor.
Replace lower tank temperature sensor.
Check the power supply to the unit and
make sure it is higher than 198 VAC.
Check the power supply to the unit and
make sure it is lower than 252 VAC.
Fill unit completely with water. Open a
nearby hot water faucet to permit air in
the system to escape. Close the hot water
faucet when water starts to flow without
air interruptions.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
Contact a qualified installer or service
agency for repair. Refer to phone number
listed on the technical support label loca-
ted on the unit.
EN
67

Publicité

loading

Ce manuel est également adapté pour:

Enevator store cawh 8-455-9Enevator store cawh 8-455-12