Dryer Error Sequence for Flashing Red LED Light
Error
1 flash every 2 seconds.
2 flashes every 2 seconds.
3 flashes every 2 seconds.
4 flashes every 2 seconds.
5 flashes every 2 seconds.
6 flashes every 2 seconds.
Dryer will not activate
Bradley • 215-1771 Rev. K: ECO 21-08-042
Basin Front
Cause
Blocked rotor
Over voltage
Overtemp controller
Overtemp motor
Under voltage
Communication error
(interface and motor control
board)
Sensor is dirty.
Air Nozzles
Location of Red
LED Dryer Light
Contact Bradley Technical Services.
Disconnect power. Check outlet voltage. If appropriate voltage, test
dryer. If problem persists contact Bradley Technical Services.
Clean or replace air filter (part number 269-2128). If problem
persists, contact Bradley Technical Services.
Clean or replace air filter (part number 269-2128). If problem
persists, contact Bradley Technical Services.
Disconnect power. Check outlet voltage. If appropriate voltage, test
dryer. If problem persists contact Bradley Technical Services.
Contact Bradley Technical Services.
Clean with a soft damp cloth.
12/31/2021
Underside of
Dryer Hood
Solution