INSTALLATION
Door Reversibility
Tool required: Philips screwdriver, Flat bladed screwdriver, Hexagonal spanner.
•
Ensure the unit is unplugged and emp ty.
•
To take the door off, it is necessary to tilt the unit backwards. You
should rest the unit on something solid so that it will not slip during the
door removing process.
•
All parts removed must be saved to do the reinstallation of the door.
•
Do not lay the unit flat as this may damage the coolant system.
•
It's better that 2 people handle the unit during assembly.
1. Unscrew top hinge cover and then unscrew the top hinge. Then lift upper
door and place it on a soft pad to avoid scratch and damage.
2. Remove the pin with a screwdriver and flip the hinge bracket. Then refit the
pin to hinge bracket.
3. Removethetopleftscrewcover.
4.Unscrew middle hinge.
10