2.Place dust tank upside down position until dry. DO
NOT use wet canister for dry pick up.
3.Place vacuum head
on a level surface until dry.
4
4.Reinstall filters when vacuum head is dry. See Filters
under Maintenance.
5.When dust tank is dry place the vacuum head
onto the canister and secure it by closing the
lid latches
.
5
Shut Down/Transportation (Fig. A)
1.Turn on/off control switch
2.Unplug the unit.
2
3.Store the power cord
handle/cord wrap
as shown.
1
4.When transporting in vehicles, secure the machine.
MAINTENANCE
The D
WALT appliance has been designed to operate
E
over a long period of time with a minimum of
maintenance.Continuous satisfactory operation
depends upon proper appliance care and regular
cleaning.
WARNING: To reduce the risk of injury,
turn appliance off and disconnect
appliance from power source before
installing and removing accessories,before
adjusting or changing set-ups or when
making repairs. An accidental start-up can cause
injury.
WARNING: For user servicing, the machine must
be dismantled, cleaned and serviced, as far as is
reasonably practicable, without causing risk to the
maintenance staff and others. Suitable precautions
include, decontamination before dismantling, provision
for local filtered exhaust ventilation where the machine
is dismantled, cleaning of the maintenance area and
suitable personal protection.
• The manufacturer, or an instructed person, shall
perform a technical inspection at least annually,
consisting of, for example, inspection of the filter for
damage, air tightness of the machine and proper
function of the control mechanism.
• When carrying out service or repair operations, all
contaminated items which cannot be satisfactorily
cleaned, are to be disposed of; such items shall be
disposed of in impervious bags in accordance with
any current regulation for the disposal of such waste.
• For dust extractors it is necessary to provide for an
adequate air change rate L in the room if the exhaust
air is returned to the room.
(NOTE: Reference to National Regulations is
necessary.)
Filter (Fig. A, H, I)
FILTER CARE
The filters included with this vacuum are long life filters.
To be effective in minimizing dust recirculation, the filters
MUST be installed correctly and in good condition.
WARNING: Appropriate personal protective
equipment like dust mask and gloves should be used
while handling the filters.
4
to the OFF position.
3
wrapping it around the top
To Remove
Clean Connect
1.Turn on/off control switch
position ( O ) and unplug cord from outlet.
2.Release lid latches
5
head
. from canister. Place vacuum head on a
4
level surface upside down.
3.Turn each filter
counterclockwise by gripping it on
9
the plastic end cover as shown, and carefully remove
from head, ensuring debris does not fall into mounting
hole.
NOTE: Use care to not damage filter material.
4.If the bottom side of the vacuum head
be cleaned, use a cloth dampened with water and
mild soap and allow it to dry. Dispose of cloth in an
appropriate container.
5.Inspect filters for wear, tears or other damage.
NOTE: If there is any doubt on the condition of the
filters they MUST be replaced. DO NOT continue use
if filters are damaged.
WARNING: Never use compressed air or a brush
to clean filters, otherwise damage to the filter membrane
will occur which will allow dust to pass through the filter.
If needed, gently tap against a hard surface or rinse with
room temperature water and let air dry. Cleaning of the
filters is typically unnecessary, even if the filter is covered
with dust. The automatic filter cleaning system
maintain maximum performance and continue to function.
If visual damage to the filter membrane exists, replace
filters. Filters typically last between six and twelve months
depending on use and care.
Clean Connect
To Install
1.Ensure filter seal
is in place and is secure.
15
2.Line up filter threads
16
using moderate force, turn filter clockwise until tight.
NOTE: Use care to not damage filter material.
3.Place the vacuum head
secure it by closing the canister latches
Empty The Tank (Fig. J)
WARNING: To reduce the risk of injury from
accidental starting, unplug power cord before emptying
the dust tank.
1.Remove the power head assembly of the wet/dry
vac bypulling outward on the lid clips located on each
side of the vac. Lift off the power head assembly.
2.Dump the tank contents into the proper waste
disposal container.
3. Liquids may be emptied through the tank drain. To
empty, turn the unit off and remove the plug from the
wall outlet. Remove the drain cap and deposit the liquid
waste contents in a suitable drain.After tank is empty,
return the drain cap to its original position. To continue
use, plug the cord into the wall outlet and turn the unit on.
16
TM
Filter
to the OFF
3
and remove vacuum
needs to
4
TM
Filter
to vacuum head threads and
onto the container and
4
.
5

Publicité