en-us Conversion to LP gas
5.2 Replacing the orifices
Remove all burner grates, burner caps and burner
1.
bases.
Remove the natural gas orifices and replace them with
2.
LP orifices using a 7 mm socket wrench. See burner
chart →  Page 17 .
For ease of installation use a small piece of tape and
insert it in the socket wrench to prevent the orifice
from falling out.
It is important to make sure that the orifices do not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
Normal burner with one orifice
Fasten the orifices.
3.
Save the orifices removed from the appliance for future
4.
use.
5.3 Adjusting the gas valves
Turn the control knobs to position off.
1.
Pull off the control knobs.
2.
Remove the screws at each burner and lift off the main
3.
top from the cooktop.
16
Remove the switch from the valve.
4.
Adjust the bypass jet on each valve with a flat blade
5.
screwdriver, with a small thin blade. Refer to the burner
chart for the correct setting of the setting screws (M).
→  "Burner chart", Page 17
Use setting
for LP Gas. The bypass jet must be
tightened properly.
Use setting
for natural gas. The bypass jet must be
loosened until the gas flow from the burner is correct.
Turn ¼ turn to the left from LP setting.
Replace the switch on the valves.
6.
Ensure that the gaskets around the burner bases are in
7.
place.
Reinstall the main top and the control knobs.
8.
Replace all burner bases, burner caps and burner
9.
grates.
Continue the installation procedure from
10.
→  "Connection overview", Page 11
When the installation is complete, verify that the
11.
appliance works properly.
→  "Checking the installation", Page 14 .
Note: In the event of damage, the valve must be
completely replaced.