Télécharger Imprimer la page

Velleman DCM115 Mode D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
9. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II and CAT III
environments (see §7).
Use this meter only in a pollution degree 2 environment (see §8).
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
relative humidity: max. 80 %
altitude: max. 2000 m (6560 ft)
voltage ........................................................................... 500 V
power supply ......................................... 2 x 1.5 V AAA/R03 (incl.)
display ............................................................ LCD, 1999 counts
display dimensions ................................................... 60 x 28 mm
over-range .......................................................................... yes
continuity buzzer .................................................................. yes
diode test ............................................................................ yes
low-battery indication ........................................................... yes
ranging mode ................................................................ manual
data hold ............................................................................ yes
backlight ............................................................................. yes
auto power-off ..................................................................... yes
dimensions ..................................................... 210 x 80 x 30 mm
weight (with battery) ......................................................... 200 g
clamp opening dimensions ................................................ 38 mm
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe .............................. CAT II 1000 V, 10 A; L = 90 cm
9.1 DC VOLTAGE
range
1000 V
Overload protection: 1000 V DC or 750 V AC rms
Impedance: 10 MΩ
V. 01 – 06/08/2018
Do not measure circuits that may contain voltages
> 1000 VDC or > 750 VAC
resolution
1 V
DCM115
accuracy
± (0.8 % rdg + 2 digits)
8
©Velleman nv

Publicité

loading