Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dial Position
Range
400V
Voltage DC/Voltage AC
1000V
400.0V
Lo-Z
Low Input Impedance
1000V
200A
Current AC
400.0Ω
4.000kΩ
Resistance
40.00kΩ
400.0kΩ
Continuity
4.000MΩ
40.00MΩ
FUNCTIONAL DESCRIPTION
3
CAT.IV
200 A
4
600 V
CAT.III
1000 V
2
5
OFF
V
V
HOLD
Lo-Z
A
6
1
7
mA
mV
mF
M
k
8
AUTO
ACDC
HOLD
Lo -
Z
C O
M
CAT.IV 600 V
V
CAT.III 1000 V
1. Light On/Off button
5. NCV indicator
2. Hold button
6. Dial
3. Jaws
7. Display
4. Light
8. Terminal inputs

Functions

Resolution
Accuracy
: ±(1.0% + 2 dgt)
0.1V/1V
: ±(1.5% + 5 dgt) 45-500 Hz
0.1V/1V
±(2.0% + 3 dgt) AC:45~500Hz
0.1A
±(3.0% + 3 dgt) 45-60 Hz
0.1Ω
±(1.0% + 5 dgt)
0.001kΩ
±(1.0% + 2 dgt)
0.01kΩ
±(1.0% + 2 dgt)
0.1kΩ
±(1.0% + 2 dgt)
0.001MΩ
±(1.0% + 2 dgt)
0.01MΩ
±(2.0% + 5 dgt)
ASSEMBLY
WARNING
Recharge only with the char-
ger specifi ed for the battery. For specifi c charg-
ing instructions, read the operator's manual
supplied with your charger and battery.
Inserting/Removing the Battery
To remove the bat-
Fig. 1
tery, use a fl at screw-
driver to pry open the
lock latch. Push in the
release buttons and
pull the battery pack
away from the tool.
Lock latch
To insert the battery,
slide the pack into the body of the tool. Make sure
it latches securely into place. Press in the lock latch
to lock the battery in place.
4
WARNING
Always turn the Rotary
Dial to OFF before inserting or removing
probes. Only use accessories specifi cally
recommended for this tool. Others may be
hazardous.
WARNING
Only use MILWAUKEE test
leads with the MILWAUKEE Fork Meters.
Inspect test leads before each use. Use meter
to run a continuity test.
Before Use
Confi rm the Rotary Dial is set to the correct position,
the instrument is set to the correct measurement
mode, and the Data hold function is disabled. Oth-
erwise, desired measurement cannot be made.
Making a Measurement
Voltage
DANGER
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over AC 1000V or DC 1000V
exists.
Keep fi ngers behind the guards and away
from test lead tips during measurements.
1. Set the Dial to
position.
2. Connect the red test lead
CAT.IV
200 A
600 V
ACV
CAT.III
1000 V
to the VΩ terminal and the
black test lead to the COM
V
V
AUTO
DCV
terminal.
3. AC: Connect the test leads
AUTO
to the circuit under test. The
V
AUTO
AC
reading is displayed.
C M
O
CAT.IV 600 V
V
CAT.III 1000 V
DC: Connect the red test
lead to the positive (+) side
and black test leads to
the negative (-) side of the
circuit under test. The reading is displayed. A
reversed connection is indicated as a negative
value.
OPERATION
Lo-Z
Low Input Impedance
Automatic voltage detection (AC or DC).
1. Set the Dial to
Lo-Z
position.
2. Connect the red test lead
to the VΩ terminal and the
black test lead to the COM
terminal.
3. AC: Connect the test leads
to the circuit under test. The
reading is displayed.
DC: Connect the red test
lead to the positive (+) side
and black test leads to the
negative (-) side of the cir-
cuit under test. The reading is displayed. A
reversed connection is indicated as a negative
value.
Current
DANGER
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over AC 1000V or DC 1000V
exists. Jaws are designed not to short the
circuit under test. If equipment under test has
exposed conductive parts, however, extra
precaution should be taken to minimize the
possibility of shorting.
Disconnect the test leads from the instrument
for current measurement.
V
AC
1. Set the Dial to
position.
2. Run the conductor
CAT.IV
600 V
V
CAT.III
1000 V
DC
through the jaws. The
reading is displayed.
A
NOTE: Do not place
2 or more wires be-
tween jaws at the
C M
O
same time. Place
wire between arrows.
Otherwise, irregular
results will occur.
CAUTION
Maximum conductor size is
approx 5/8" diameter.
5
CAT.IV
200 A
600 V
ACV
CAT.III
1000 V
V
Lo-Z
AUTO
Lo -
AC
Z
DCV
V
AUTO
Lo -
DC
Z
V
AUTO
AC
Lo -
Z
C M
O
CAT.IV 600 V
V
CAT.III 1000 V
200 A
CAT.IV
200 A
600 V
CAT.III
1000 V
A
CAT.IV
AC
600 V
200 A
CAT.III
1000 V
CAT.IV 600 V
V
CAT.III 1000 V
CAT.IV
200 A
600 V
CAT.III
1000 V

Publicité

Table des Matières
loading

Table des Matières