a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
The hood is provided with a special power cable ; if the cable
is damaged, request a new one from Technical Service.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Operation
The control panel consists of a backlit rotating disk.
•To put on and off the lights:
Press on the disk (T) to put on and off the lights
• To select the available suction speeds:
Turn the disk (T) clockwise to turn on and increase the suction
speed and counter-clockwise to decrease it, and to turn off the
hood.
The crown (L) lights to indicate the selected suction speed:
• L1 lit
speed 1 (minimum).
• L1 + L2 lit
speed 2 (medium).
• L1 + L2 + L3 lit
Speed 3 (maximum).
• L1 + L2 + L3 + L4 lit in flashing mode
Speed 4 (intensive), lasting for 5 minutes, then the hood is
placed automatically at speed 2
• L off:
Suction motor off
Filters' Saturation Control
The hood is equipped with a device that indicates when it is
required to perform the filter maintenance
The saturation control device of the grease filter is always
active
The control device of the activated carbon filter is usually
turned off
To activate it, proceed as follows:
- Turn off the hood.
- Press the disk (T) for more than 5 seconds
The crown (L) lights completely, flashing, and a beep will be
heard: the control device of the charcoal filter is activated.
NB = to turn it off, turn off the hood, press the disk (T), L1 + L2
will be backlit, flashing; wait for the beep to confirm the
deactivation.
Grease filter saturation indicator
L1 + L2 flash when you have to perform maintenance of the
grease filter
Activated charcoal filter saturation indicator
L3 + L4 flash when you have to perform maintenance of the
activated charcoal filter
Reset of filter saturation signal
After filter maintenance, turn on the hood and press the disk
(T) for more than 5 seconds: you will hear a long tone (beep)
confirming the reset.
Note: In case of simultaneous signaling (grease filter and
activated charcoal filter saturation), you must repeat the reset
twice.
16