3.2 SINGLE-POLE APPLICATION
To:
Detect breaks in conductors in walls or in a floor;
Locate and trace lines, outlets, junction boxes, switches, etc., in domestic
installations;
Locate bottlenecks, twists, deformations, and obstructions in piping installations
using a metal wire.
3.2.1
LOCATING AND TRACING LINES AND OUTLETS
Preconditions:
The circuit must be dead.
•
The neutral wire and the protection earth wire must be connected and
•
perfectly operational.
Connect the transmitter to the phase and to the protection earth wire as
•
shown in Fig. 10.
C.A 6681 Cable locater
English
Fig.10
49