Warning
• This Comelit product was designed for use in the creation of security and home automation systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• Cut off the power supply before carrying out any maintenance procedures.
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in
the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems,
by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
Module on bus has 8 inputs + 1 scenario input, as well as 8 relay outputs with switching contact with independent common capable of
controlling resistive electrical loads up to 16A. For non-resistive loads, it is best to use a support contactor at each output.
Power supply voltage
Absorption
Inputs
Outputs
Loads controlled
Max. input cable length
Protection
Indications
Lack and restoring of power supply
Terminals
Positioning
Applicable standards
Approvals
Operating temperature
Storage temperature
Relative air humidity
Weight
Dimensions
-
BUS power supply negative
+
BUS power supply +24 Vdc
D
BUS data line
K
Common
V-
Support negative
V+
+24 Vdc support
I8
Input 8
I7
Input 7
I6
Input 6
I5
Input 5
I4
Input 4
I3
Input 3
I2
Input 2
• The module must be programmed vis the BUS line, using the SimpleHome/RS232 interface (20022611) and the SimpleProg
programming software.
• We recommend connecting continuously powered loads to the NC terminal.
• Specifications are subject to change without notice.
ART. 20046606
TECHNICAL CHARACTERISTICS
24 Vdc ± 5%
min. 8 mA, max. 220 mA
8+1, optically coupled digital type
8 relay 230 Vac, resistive 16A (cosϕ = 1)
Max. absorption per individual output:
resistive loads (cosϕ=1): 16A
LED bulbs: 100 W
electronic transformers: 100 W
230 VAC motors: 350 W - 16A
25 m
against reverse polarity
1 bus status indicator LED: when flashing, indicates data transmission via bus, when lit steadily
indicates lack of power supply negative or incorrect device connection.
9 input status indicator LEDs / 8 output status indicator LEDs
output status memory
removable for BUS connection
On a DIN rail on a dedicated control panel or in junction boxes *
electromagnetic compatibility: EN 50081-1 (interference emission) and
EN50082-2 (resistance to interference)
CE
0° to 50°C
-10° to +70°C
5 to 95% with no condensation
380 g (not including packaging)
160 x 90 x 58 mm (9 DIN modules)
CONNECTION TERMINALS
I1
Input 1
IS
Multiple command (scenario)
NO1
Output 1 – NO contact
C1
Output 1 – Common
NC1
Output 1 – NC contact
NO2
Output 2 – NO contact
C2
Output 2 – Common
NC2
Output 2 – NC contact
NO3
Output 3 – NO contact
C3
Output 3 – Common
NC3
Output 3 – NC contact
NO4
Output 4 – NO contact
C4
Output 4 – Common
NC4
Output 4 – NC contact
NO5
Output 5 – NO contact
C5
Output 5 – Common
NC5
Output 5 – NC contact
NO6
Output 6 – NO contact
C6
Output 6 – Common
NC6
Output 6 – NC contact
NO7
Output 7 – NO contact
C7
Output 7 – Common
NC7
Output 7 – NC contact
NO8
Output 8 – NO contact
C8
Output 8 – Common
NC8
Output 8 – NC contact
3

Publicité

loading