20. If necessary, remove the adapter from the flushing circuit and recon-
nect all the components to the refrigerant circuit.
Fit the connections of the AirConServiceCenter to the vehicle air
conditioning system and open them.
21. In the basic menu, use the cursor keys  or  to select
"Free selection":
22. Press ENTER to confirm.
23. If necessary, use the keypad (7) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next pro-
gram step.
24. Deselect "Rec/Recycling phase" using No (the setting flashes) and
press ENTER to confirm.
25. Select "Vacuum phase" (the setting flashes) and press ENTER to
confirm.
26. If necessary, use the keypad (7) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next pro-
gram step.
27. Select "Filling phase" (the setting flashes) and press ENTER to
confirm.
28. Enter the refrigerant filling quantity (note the oil filling quantity of the
compressor).
29. Then follow the instructions on the display (6):
Select the setting (which then flashes) and press ENTER to confirm.
30. Select "Process start" by pressing ENTER.
✓ After filling is complete, you will be prompted to disconnect the hoses
of the AirConServiceCenter from the vehicle air conditioning system.
31. Disconnect the service hoses (10) and (11) and press ENTER to
confirm.
The service hoses will now be drained. The unit is then ready for
further use.
32. Put the valve caps of the vehicle air conditioning system back on the
connections.