Step 6: Electrical Requirements, Connection & Grounding
--
Before installing, turn power OFF at the service panel.
ON accidentally.
MODEL
TYPE
30"
36"
36" with griddle
48" with griddle
For these gas range models, a neutral supply wire
must be provided from the power source (breaker)
because critical range components, including the
surface burner spark reignition modules, require 120
VAC to operate safely and properly. An improper 120
VAC power supply will cause malfunction, damage to
this appliance, and possibly create a condition of shock
hazard. If the correct power supply circuit is not
provided, it is the responsibility and obligation of the
installer and user to have proper power supply
connected. This must be accomplished in accordance
with all applicable local codes and ordinances by a
qualified electrician. In the absence of local codes and
ordinances, the power supply connection shall be in
accordance with the National Electrical Code.
Observe all governing codes and ordinances when
grounding. In the absence of these codes or
ordinances observe National Electrical Code ANSI/
NFPA No. 70 current issue.
Chart B: Electrical Supply Circuit Requirements
VOLTAGE
120 VAC
120 VAC
120 VAC
120 VAC
Lock service panel to prevent power from being turned
CIRCUIT
FREQUENCY
RATING
10 Amps
10 Amps
20 Amps
20 Amps
Electric wiring diagrams and schematics have been
placed in the kick panel area of the range for access by
a qualified service technician (refer to Figure 4 on
page 9).
Before you plug in an electrical cord, be sure all
controls are in the OFF position.
For appliances equipped with a cord and plug, do not
cut or remove the ground prong. It must be plugged
into a matching grounding type receptacle to avoid
electrical shock. If there is any doubt as to whether the
wall receptacle is properly grounded, the customer
should have it checked by a qualified electrician.
INSTALLER — show the owner the location of the
circuit breaker. Mark it for easy reference.
IMPORTANT:
Dedicated 20 AMP service is required for range with
electric griddle.
PHASE
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single