Installation Clearances - Thermador Professional PRO HARMONY PRG30 Manuel D'installation

Masquer les pouces Voir aussi pour Professional PRO HARMONY PRG30:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Clearances

30" (762mm) min. from bottom
of Overhead Hood to cooking
surface.
36" (914mm) min. If
hood contains combustible
18" (457mm)
materials.
minimum
*35
" (911mm) Min. range height
with leveling legs fully retracted.
*36 ¾" (933mm) Max range height
with leveling legs fully extended.
For 30" Ranges {30" (762mm) or 36" (914mm) Wide Hood
{36" (914mm) or 42" (1067mm) for Island
For 36" Ranges {36" (914mm) or 42" (1067mm) Wide Hood
{42" (1067mm) or 48" (1219mm) for Island
For 48" Ranges {48" (1219mm) 54" (1372mm), or 60" (1524mm) Wide Hood
{54" (1372mm) for Island
30" Range — 30" (762mm)
36" Range — 36" (914mm)
48" Range — 48" (1219mm)
Min. distance between overhead cabinets
of combustible material
RANGE WIDTH
For 30" Ranges — 30" (762mm)
For 36" Ranges — 36" (914mm)
For 48" Ranges — 48" (1219mm)
For Electrical & Gas Supply zones,
see Figure 3a on Page 7.
as defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1 scope
and are not certified by CSA. Clearances of less than 12" (305 mm) must be
approved by the local codes and/or by the local authority having jurisdiction.
*The range height is adjustable. The level of the range top must be at the same
level or above the counter top level.
13" (330mm)
Max Cabinet
Depth
5" (127mm)
min. to
combustible
sidewall
material
(both sides).
CAUTION!
See Figure 2
36" (914mm) Min
to combustible
material
from Cooking
Surface
Cooking
Surface
Figure 1: Cabinet Clearances
English 5

Publicité

Table des Matières
loading

Table des Matières