Technical Data
Mechanical Data
Mechanical principle:
Enclosure:
Internal parts:
Locking force:
Operating speed
min. / max.:
Output
Max. switching frequency:
Mechanical life:
General Data
Temperature range:
Storage temperature:
Intended use:
Mounting:
Test principles:
Ordering Example
STS- M 10 B 01 M /K
Translatory actuator or key movement
is converted into relative movement by
mechanical components
PA + GF
Stainless steel V4A / AISI 316 / AISI 630
(acc. to EN 10027-2;
1.4401; 1.4404; 1.4542;
1.4301; 1.4310)
F
2000 N
zh
100 / 250 mm/s
360/h
1 x 10
switching cycles
6
- 25°C to + 45°C
- 25°C to + 60°C
Up to max. cat. 4, PL e according
DIN EN ISO 13849-1
According to DIN EN 50041
DIN EN ISO 13849-1:2015
DIN EN ISO 14119:2014-03
DIN EN 60947-5-1:2017
GS-ET-15:2019-06
GS-ET-19:2019-06
GS-ET-31:2010-02
FRP
End module M/K
Key module 01/K
Actuator module B/K
Key module 10/K
End module M/K
Safety Related Data
Data suitable for the PFH
summation method according
D
to EN ISO13849-1: 2016
Data
M10B01M/K
according to
EN
ISO13849-1:
2016
Category
2
PL
d
PFH
3.18299E-09 2.05378E-09 1.63371E-09 2.00244E-10
D
T
20
10D
CCF
65 ...100
required
B
2 x 10
6
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostics
Coverage
60 %
ratio DC
Test interval
1 / year
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2
actuators must be used
PFH
:
When used as a „stand-alone unit" (not as part of a key trans-
D
fer system), the safety parameters in the table above apply
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
D
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
22
SAFEMASTER STS/K-M10B01M/K / 11.01.21 en / 335A
M10BB01M/K
3
3
d
e
20
20
85 ...100
85 ...100
85 ...100
2 x 10
6
2 x 10
6
2 x 10
365
365
24
24
1
1
8760
8760
60 %
90 %
1 / year
1 / month
1 / month
+ ... PFH
D1
4
e
20
6
365
24
1
8760
99 %
Dn